Basic Info.
Model NO.
Yste180c
Water Consumption
Less Than 6L/H.
Power Supply
AC 220V±22V 50Hz±1 Hz.
Humidity
More Than 70%
Frequency
550 Va.
Weight
60kg
Dimension
782mm×581mm×545mm
Transport Package
Wooden Carton
Specification
CE certificate
Trademark
YSENMED
Origin
Guangzhou
Production Capacity
1, 000 Sets / Year
Product Description
Medical Full auto chemistry analyzer
Yste180c
Throughput constant 180 T/h or 300T/h, best for middle or small size hospital
Closed integrated photovoltaic systems, no mechanical parts, maintenance free
Minimum reaction volume is 150UL, cost saving
Discrete, random access, automatic
Random choice of method, the real discrete automatic chemistry analyzer
This automatic chemistry analyzers have gained a lot of national patents during the researching.
Analyze Unit
L Throughput: Constant 180 T/h, 81 reaction cuvette positions, multi-channel testing together.
L Minimum reaction volume is 150μ L, cost saving.
L Determined by the sample sequence, inserted at any time emergency.
L Heating method: Direct thermal solid thermostat closed.
Optical Unit
L Closed integrated photovoltaic systems, no mechanical parts, maintenance free.
L Light Source: Halogen-tungsten lamp;
L Lifetime≥ 2000 h.
L 8 Wavelength, support single or dual wavelength.
Reagent Unit
L 60 reagent positions.
L Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
L 15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
L Support for single and double reagent, reagent completely open.
Internal barcode reader (option).
Sample Unit
L 60 sample positions.
L Testing according setting, random access.
L Real time display of testing status.
L Internal barcode reader (option).
Reagent/Sample handing Unit
L Intelligent liquid detection & collision protection (Red light: Collision; Blue light: Detection of the liquid).
L Reagent volume: 2 ~ 500μ L, step by 1μ L.
L Probe cleaning: Automatically washing for both inside and outside, carry over0.1%.
L Automatically dilute and retest.
Calibration and quality control Unit
L Linear curve type: Single-point linear, two-point linear and multi-point linear.
L Nonlinear curve type: Logit-4p, Logit-5p, polynomial, factor.
L Automatically use best calibration curve and standard.
L Quality control chart: L-J, Westgard TwinPlot, Cumulative.
Operation Unit
L Operation system: Windows XP/Office 2000, interface is intuitive and operate it easily, arbitrary operating authority; No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
L Can print the contents of any custom; Offers a variety of print formats.
L Help and operation guide on line in English.
L No restrictions on setting test parameters.
L Unique password for user management, rational allocation of user rights.
L Real time display of testing status, the remaining amount of reagent, testing status, reaction curve and the test progress.
L Real time display of reaction plate temperature.
RS-232 standard interface, support for the hospital network, print reports remotely.
Others
L Temperature: 10-30 degree
L Humidity: Less than 70%.
L Try to avoid strong light.
L Floor level up: Less than 1/200.
L Barometric: 86.0kPa-106.0kPa.
L Power Supply: AC 220V± 22V 50Hz± 1 Hz.
L Water consumption: Less than 6L/h.
L Frequency: 550 VA.
L Dimension: 782mm× 581mm× 545mm
L Weight: 60kg
Test projects
L ALT, AST, TP, ALB, TBIL, DBIL, ALP, r-GT, CHE, TBA, 5-NT
L UREA, CR, UA, TCO2
L CHOL, TG, HDL, LDL, ApoA, ApoB, LPa
L AMY, LIP
L GLU, GSP
L CK, CK-MB, a-HBDH, LDH, MB
L CRP, RF, ASO
Specifications
We listed some hospital basic items for your reference as below:
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!
Yste180c
Throughput constant 180 T/h or 300T/h, best for middle or small size hospital
Closed integrated photovoltaic systems, no mechanical parts, maintenance free
Minimum reaction volume is 150UL, cost saving
Discrete, random access, automatic
Random choice of method, the real discrete automatic chemistry analyzer
This automatic chemistry analyzers have gained a lot of national patents during the researching.
Analyze Unit
L Throughput: Constant 180 T/h, 81 reaction cuvette positions, multi-channel testing together.
L Minimum reaction volume is 150μ L, cost saving.
L Determined by the sample sequence, inserted at any time emergency.
L Heating method: Direct thermal solid thermostat closed.
Optical Unit
L Closed integrated photovoltaic systems, no mechanical parts, maintenance free.
L Light Source: Halogen-tungsten lamp;
L Lifetime≥ 2000 h.
L 8 Wavelength, support single or dual wavelength.
Reagent Unit
L 60 reagent positions.
L Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
L 15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
L Support for single and double reagent, reagent completely open.
Internal barcode reader (option).
Sample Unit
L 60 sample positions.
L Testing according setting, random access.
L Real time display of testing status.
L Internal barcode reader (option).
Reagent/Sample handing Unit
L Intelligent liquid detection & collision protection (Red light: Collision; Blue light: Detection of the liquid).
L Reagent volume: 2 ~ 500μ L, step by 1μ L.
L Probe cleaning: Automatically washing for both inside and outside, carry over0.1%.
L Automatically dilute and retest.
Calibration and quality control Unit
L Linear curve type: Single-point linear, two-point linear and multi-point linear.
L Nonlinear curve type: Logit-4p, Logit-5p, polynomial, factor.
L Automatically use best calibration curve and standard.
L Quality control chart: L-J, Westgard TwinPlot, Cumulative.
Operation Unit
L Operation system: Windows XP/Office 2000, interface is intuitive and operate it easily, arbitrary operating authority; No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
L Can print the contents of any custom; Offers a variety of print formats.
L Help and operation guide on line in English.
L No restrictions on setting test parameters.
L Unique password for user management, rational allocation of user rights.
L Real time display of testing status, the remaining amount of reagent, testing status, reaction curve and the test progress.
L Real time display of reaction plate temperature.
RS-232 standard interface, support for the hospital network, print reports remotely.
Others
L Temperature: 10-30 degree
L Humidity: Less than 70%.
L Try to avoid strong light.
L Floor level up: Less than 1/200.
L Barometric: 86.0kPa-106.0kPa.
L Power Supply: AC 220V± 22V 50Hz± 1 Hz.
L Water consumption: Less than 6L/h.
L Frequency: 550 VA.
L Dimension: 782mm× 581mm× 545mm
L Weight: 60kg
Test projects
L ALT, AST, TP, ALB, TBIL, DBIL, ALP, r-GT, CHE, TBA, 5-NT
L UREA, CR, UA, TCO2
L CHOL, TG, HDL, LDL, ApoA, ApoB, LPa
L AMY, LIP
L GLU, GSP
L CK, CK-MB, a-HBDH, LDH, MB
L CRP, RF, ASO
Specifications
Ysenmed ® Yste180c Automatic Chemistry Analyzer | Specifications | ||
Analyze Unit | |||
Throughput | Constant 180T/h (non-ISE) | ||
Theory | Absorption spectrometry, transmission turbidimetry | ||
Methodology | End-point Fixed-timeKineticIon selective electrode | ||
Test according set up, random access | |||
Reaction plate | Contain 81 reaction cuvettes | ||
Maximum reaction time | 15 minutes | ||
Minimum reaction volume | 150 ul | ||
Material of cuvettes | Special UV-transparent optical glass | ||
Cuvettes use | Automatically cuvettes washing | ||
Optical Unit | |||
Light Source | Halogen-tungsten lamp | ||
Photometer | Reversed optics | ||
Wavelength | 340nm-900nm wavelength option | ||
Absorption | 0-4 Abs | ||
Reagent Unit | |||
Reagent plate | 60 reagent positions ,support for single and double reagent, reagent completely open | ||
Reagent storage temperature | 2~10 degree | ||
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml | ||
Reagent volume | 20-500 ul, step by 1.0 ul | ||
Reagent/Sample Probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | ||
Sample Unit | |||
Sample plate | 60 sample positions | ||
Sample type | Human (animal) serum plasmaurine etc. | ||
Samples cup | Support one-off micro cups | ||
Sample volume | 2-100 ul, step by 0.1 ul | ||
Sample/reagent probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | ||
Temperature control Unit | |||
Heating method | Direct thermal solid thermostat closed | ||
Temperature equilibrium time | <3 minutes | ||
Reaction temperature | 37 ±0.1 degree | ||
Temperature fluctuation | ±0.1 degree | ||
Operation Unit | |||
Software | WindowsXP 2000 | ||
Database | SQL Server | ||
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | ||
Print format | Can be set up, offer several standard format | ||
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | ||
Quality control methods : | Real time, within day & between day | ||
Quality control diagram | L-J cumulativetwin plot | ||
Status display | Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray | ||
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | ||
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | ||
Others | |||
Water consumption : < 6L/h | Power Supply :AC 220V±22V 50Hz±1Hz | ||
Frequency :Maximum 600VA | Dimension :782mm×581mm×545mm | ||
Net Weight : 60kg | Accessory :Software |
We listed some hospital basic items for your reference as below:
One-stop shopping Hospital medical equipment | X ray room | X ray machine |
Processor | ||
X ray film | ||
Cassette | ||
Intensifying screen | ||
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar) | ||
Ultrasound | B/w 2D ultrasound | |
2/3/4D color ultrasound | ||
Laboratory room | Chemistry analyzer | |
Hematology analyzer | ||
Microplate elisa reader | ||
Microplate washer | ||
Centrifuge | ||
Pipette | ||
Water bath | ||
Urine analyzer | ||
Operation room | Anesthesia machine | |
Ventilator | ||
Operating lamp | ||
Operation table | ||
Pendant | ||
Medical drill and saw | ||
ECG | ||
Patient monitor | ||
Defibrillator | ||
Infusion pump | ||
Electrocoagulation | ||
Oxygen generator | ||
Electric suction device | ||
Autoclave sterilizer |
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!