Victor 26h Multifunction Process Calibrator with Hart Communication Digit Display Process Calibrator Signal Generator

Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year

Products Details

Basic Info.

Model NO.
VICTOR 26H
Certification
RoHS, CE
Color
Blue
Type
Infrared Life Detector
Transport Package
Carton
Trademark
VICTOR
Origin
China
Production Capacity
50000PCS/Month

Product Description

VICTOR26H Multifunction Process Calibrator HARTCommunication With Accuracy 0.01% 5 Digits Display 24V loop circuit IP65
Protection Grade: IP65
Multifunction Process Calibrator with HART Communication

Statement: this is applied to both HART type and Basic type multifunction process calibrators. Illustrations concerned with HART operations can be applied only to HART type. All explanations and examples are made on HART type.
 
Standard Accessories
Make sure that the package contains all the accessories listed below. And if you find they are damaged or any of them is missing,
please contact the vendor from which you purchased the product as soon as possible. Refer to the replacing part list in 15.3 in
the Manual if you want to order the replacing parts.

§ One pair of Testing Probe(H000000-00)
§ One pair of Industrial testing Lead(H000001-00)
§ One pair of Industrial testing Lead (H000002-00)
§ One pair of hook Testing Probe (H000004-00)
§ One pair of Alligator clip(H010000-00)
§ One pair of Alligator clip(H010007-00)
§ One set of RTD Convertor(H200000-00)
§ One copy of A User's Manual
§ One copy of Certification of Warranty
§ Two pieces of Fuse Tube(100mA/250V)
§ Two pieces of Fuse Tube(50mA/250V)
§ Four alkaline batteries
One Bag
Specification
Project
Model
Performance
parameters
VICTOR 26
VICTOR 26H
Source
DC millivolt
Range
-5 ~ 110mV
-5 ~ 110mV
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%
0.01%+0.01%
Resolution
1uV
1uV
DC voltage
Range
-1 ~ 11V
-1 ~ 11V
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%
0.01%+0.01%
Resolution
10uV/0.1mV
10uV/0.1mV
DC current
Range
0 ~ 33mA
0 ~ 33mA
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%
0.01%+0.01%
Resolution
1uA
1uA
Sink current
Range
0 ~ 33mA
0 ~ 33mA
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%
0.01%+0.01%
Resolution
1uA
1uA
External power
supply
5 ~ 28V
5 ~ 28V
Resistance
Range
0 ~4KΩ
0 ~4KΩ
Accuracy=
±(% of the set value+% of range)
0.01%+0.01%
0.01%+0.01%
Resolution
0.01Ω/0.1Ω
0.01Ω/0.1Ω
Thermocouple
Range
R/S/K/E/J/T/B/N/L/U
R/S/K/E/J/T/B/N/L/U
Accuracy
0.4ºC
0.4ºC
Resolution
0.1ºC/1ºC
0.1ºC/1ºC
RTD
Range
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Accuracy
0.2ºC
0.2ºC
Resolution
0.1ºC
0.1ºC
Frequency
(Hz)
Range
1Hz ~110KHz
1Hz ~110KHz
Accuracy
±2words
±2words
Resolution
0.01Hz/1Hz/0.1KHz/2KHz
0.01Hz/1Hz/0.1KHz/2KHz
Frequency(CMP)
Range
60~1200 CPM
60~1200 CPM
Accuracy
±2words
±2words
Resolution
1CPM
1CPM
Pulse
Frequency
1Hz ~10KHz
1Hz ~10KHz
Range
1 ~100000cyc
1 ~100000cyc
Accuracy
±2words
±2words
Resolution
1cyc
1cyc
Switch
Range
1Hz ~110KHz
1Hz ~110KHz
Accuracy
±2
±2
Resolution
0.01Hz/1Hz/0.1KHz/2KHz
0.01Hz/1Hz/0.1KHz/2KHz
Pressure
Range
Depends on the pressure module
Depends on the pressure module
Accuracy=
±(% of the set value+% of range)
Depends on the pressure module
Depends on the pressure module
Resolution
5 digit display
5 digit display
Measurement
DC millivolt
Range
-5 ~ 550mV
-5 ~ 550mV
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%
0.01%+0.01%
Resolution
1uV/10uV
1uV/10uV
DC voltage
Range
-0.5 ~ 35V
-0.5 ~ 35V
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%
0.01%+0.01%
Resolution
0.1mV/1mV
0.1mV/1mV
DC current
Range
-5 ~ 55mA
-5 ~ 55mA
Accuracy
±( % of Reading+ % of Range)
0.01%+0.01%
0.01%+0.01%
Resolution
1uA
1uA
Resistance
Range
0 ~5.5KΩ
0 ~5.5KΩ
Accuracy=
±( % of Reading+ % of Range)
0.01%+0.01%
0.01%+0.01%
Resolution
0.01Ω/0.1Ω
0.01Ω/0.1Ω
Thermocouple
Range
R/S/K/E/J/T/B/N/L/U
R/S/K/E/J/T/B/N/L/U
Accuracy
0.7ºC
0.7ºC
Resolution
0.1ºC/1ºC
0.1ºC/1ºC
RTD
Range
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Pt100/Pt200/Pt500/
Pt1000/Cu10/Cu50
Accuracy
0.4ºC
0.4ºC
Resolution
0.1ºC
0.1ºC
Frequency
(Hz)
Range
3Hz ~50KHz
3Hz ~50KHz
Accuracy
±2words
±2words
Resolution
0.01Hz
0.01Hz
Frequency(CMP)
Range
180~3000000 CPM
180~3000000 CPM
Accuracy
±2words
±2words
Resolution
1CPM
1CPM
Switch
Range
CLOSE/OPEN
CLOSE/OPEN
Threshold
200 ~300Ω
200 ~300Ω
Pressure
Range
Depends on the pressure module
Depends on the pressure module
Accuracy=
±( % of Reading+ % of Range)
Depends on the pressure module
Depends on the pressure module
Resolution
5 digit display
5 digit display
Continuity beeper
Range
0 ~500Ω
0 ~500Ω
Accuracy
≤50Ωsound
≤50Ωsound
Resolution
0.01Ω
0.01Ω
Loop power supply
Range
24V
24V
Accuracy
±10%
±10%
The maximum current
22mA
22mA
HART
 
×
Other functions
Backlight
Auto Power-off
Charging function
Room temperature display
Battery detection
The ramp signal
Communication function
RS232 serial communication, can realize remote control instrument by the device driver software.
RS232 serial communication, can realize remote control instrument by the device driver software.
Characteristic
Safety
EN61010-1:2001
EN61010-1:2001
Withstand voltage
The input and output AC350V/1 minutes
The input and output AC350V/1 minutes
Insulation
The input and output DC500V /50MΩ.
The input and output DC500V /50MΩ.
EMC
EN61326-1:2006
EN61326-1:2006
Authentication
CE
CE
Display
3.2" TFT screen
3.2" TFT screen
Power supply
4×1.5V AA Alkaline battery
4×1.5V AA Alkaline battery
Size
206 × 97 × 60 mm
206 × 97 × 60 mm
Weight
about 633g
about 633g
Standard Quantity Per Carton
6pcs
6pcs
Standard Carton Measurement
530mm*405mm*310mm
530mm*405mm*310mm
Standard Carton Cross Weight
12.6kg
12.6kg
Victor 26h Multifunction Process Calibrator with Hart Communication Digit Display Process Calibrator Signal GeneratorVictor 26h Multifunction Process Calibrator with Hart Communication Digit Display Process Calibrator Signal GeneratorVictor 26h Multifunction Process Calibrator with Hart Communication Digit Display Process Calibrator Signal Generator
 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours