- Overview
- Product Description
- Product Parameters
- Detailed Photos
Basic Info.
Model NO.
GF312B
LCD Display
With LCD Display
Customized
Customized
Accuracy Class
0.05, 0.1%, 0.2%
Harmonic
2ND-63st
Phase Angle Range
0 ~ 360
Frequency Range
45Hz-65Hz
Power Factor Range
-1 ~ 0 ~ 1
Keyword
Three Phase Electric Meter Calibration
Model
Three Phase Electric Meter Calibration Equipment
GF312b
Three Phase Electric Meter Calibration Equipment W
Host Weight (mm)
3
Relative Humidity
30%-85%
Transport Package
Standard Export Wooden Box
Specification
390*200*160mm
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
100sets/Month
Product Description
Three Phase Electric Meter Calibration equipment with Printer
GF312B portable three phase electric meter calibration equipment with printer is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave.
Features
Three phase active or reactive electricity energy meter
Calibrate three phase, single phase, active or reactive meter error
Measure U(voltage) of three phase or single phase
4Measure I(current) of three phase or single phase
Measure active power of three phase or single phase
Measure reactive power of three phase or single phase
Measure apparent power of three phase or single phase
Measure power factor of three phase or single phase
Measure phase angle between voltage and current
Measure frequency of power line
Display vector diagram
Display waveform of U and I
Analyze and display content of harmonic of U and I
Store and check measured data
Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp
Measure CT variable ratio
Print the data of measurement on site
GF312B portable three phase electric meter calibration equipment with printer is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave.
Features
Three phase active or reactive electricity energy meter
Calibrate three phase, single phase, active or reactive meter error
Measure U(voltage) of three phase or single phase
4Measure I(current) of three phase or single phase
Measure active power of three phase or single phase
Measure reactive power of three phase or single phase
Measure apparent power of three phase or single phase
Measure power factor of three phase or single phase
Measure phase angle between voltage and current
Measure frequency of power line
Display vector diagram
Display waveform of U and I
Analyze and display content of harmonic of U and I
Store and check measured data
Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp
Measure CT variable ratio
Print the data of measurement on site
Electrical parameters | |
---|---|
Accuracy class | 0.05, 0.1%, 0.2% |
Power supply | 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz |
Test Voltage | |
Range | 0V-600V |
Error | ±0.05% (30V-600V) ±0.1% (5V-30V) |
Harmonic | 2nd-63st |
Test Current | |
Range (direct connection) | 20mA-20A |
Error (direct connection) | ±0.05% (100mA-20A) ±0.1% (20mA-100mA) |
Range (Clamp CT) | 10mA-3000A |
Error (Clamp CT) | ±0.2% (100mA-3000A) ±0.5% (10mA-100mA) |
Harmonic | 2nd-63st |
Power measure error | |
Active power (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive power (direct connection) | ±0.1% (0.1A-20A) |
Energy measure error | |
Active energy (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive energy (direct connection) | ±0.1% (0.1A-20A) |
Phase angle | |
Range | 0° ~ 360° |
Resolution | 0.01° |
Error | ±0.05° |
Frequency | |
Range | 45Hz-65Hz |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Power factor | |
Range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Error | 0. 0005 |
Pulse output | |
Energy constant | 180000imp/kWh, 1800imp/kWh, 18imp/kWh |
Pulse ratio | 1:1 |
Output level | 5V |
Pulse input | |
Input channel | 1 |
Input level | 5-24V |
Input frequency | Max. 2MHz |
Display | |
Resolution | 6"TFT (640×480) |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Communication port | RS232 |
Communication with PC | Yes |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 390×200×160 |
Host Weight (mm) | 3 |
Weight (including Accessories 3pcs 100A clamp CT) (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to 40°C |
Relative humidity | 30%-85% |