TD3600 Three-Phase Energy Meters Test Bench

Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent for Service

Products Details

  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3600
Power
Electricity
Voltage Output
576V
Current Output
120A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
class 0.02 or 0.05
Fundamental Frequency
45 Hz ~ 100 Hz
Minimum current output
0.2 mA
Multi-position platform
3,6,12,16 positions
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
200.00cm * 100.00cm * 90.00cm
Package Gross Weight
80.000kg

Product Description

TD3600 Verification Apparatus for Three-Phase Energy Meters
TD3600 Three-Phase Energy Meters Test Bench
 

1. Summary

TD3600 is applied for the verification of new three-phase energy meters. It mainly consists of three-phase precision standard power source, verification platform, measurement and control platform, PC(optional) and verification software. TD3600 Supports simultaneous verification of 3 ~ 16 three-phase energy meters with the same voltage/current range, different meter constant.
 

2. Verification Items

  1. Test of no-load
  2. Starting current test
  3. Intrinsic error
  4. Meter constant
  5. Daily reckoning error

3. Features

3.1 Basic Features

  1. Maximum output capacity: 576 V / 120 A
  2. Fundamental frequency: 45 Hz ~ 100 Hz.
  3. Accuracy: class 0.02 or 0.05.
  4. Minimum current output: As low as 0.2 mA.
  5. Auto range: Automatic range switching and load matching.
  6. Energy measurement: Positive / negative active and reactive energy. 
  1. Daily reckoning error test: Built in standard clock tester.
  1. Automatic patrol inspection: Support automatic patrol inspection.
  2. Connection: Equipped with special pressure gauge holder.
  3. Communication: DUT through RS-485 port.
  4. Energy pulse: Electric and optical pulse sampling ports.
  5. Multi-position verification platform: Optional 3,6,12,16 positions.
  6. Mobile control unit: LCD touch screen for value output.
  7. Professional verification software: Support semi-automatic or fully automatic verification of the DUT, data management and certificate export. The software has the function of single point multiple tests, the test interval can be set, and the error curve can be drawn automatically.
 

3.2 Optional Features

  1. Offering compatibility with both single-phase and three-phase: The Potential Transformer Offer compatibility with both single-phase and three-phase. Up to 12 test positions.
  2. Current Transformer: The Current Transformer add the capability to test energy meter without keeping its voltage terminal separate from its current terminal. Up to 12 test positions.
  3. Harmonic output function: The 2nd ~ 21st @ 50 Hz / 60 Hz, harmonic content and phase are programmable.
  4. Standard meter: Class 0.05 or 0.02

4. Specifications

4.1 AC Voltage Output 

Range Resolution Short-term Stability
( % / min )
Accuracy
±(ppm of reading + ppm of range) [1]
Distortion Factor
( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
60 V 0.1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
120 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
240 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
480 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 6 V~576 V, 6-digits display, Load capacity: 15VA/ (phase · position)
  2. Symmetry: Voltage ≤ 0.2%, Phase ≤ 0.5°
  3. Protective function: Short-circuit protection, Overload protection
 

4.2 AC Current Output 

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) 
Distortion Factor
( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
5 mA 10 nA 0.03 0.02 400 + 300 240 + 160 < 1
10 mA 0.1 μA 0.02 0.01 300 + 200 120 + 80 < 0.5
20 mA 0.1 μA 0.02 0.01 300 + 200 120 + 80 < 0.5
50 mA 0.1 μA 0.02 0.01 200 + 50 60 + 40 < 0.5
100 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
200 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
500 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
1 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
2 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
5 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
10 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
20 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
50 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
100 A 1 mA 0.01 0.005 200 + 50 60 + 40 < 0.5
  1. Output range: 0.2 mA~120 A, 6-digits display, Load capacity: 30VA/ (phase · position)
  2. Symmetry: Current ≤ 0.5%, Phase ≤ 0.5°
  3. Protective function: Open-circuit protection, Overload protection
 

4.3 Frequency / Phase

Accuracy Class 0.05 Class 0.02
Frequency Measuring Range 45 Hz~100 Hz 45 Hz~100 Hz
Minimum Resolution 0.000 01 Hz 0.000 01 Hz
Accuracy ±0.005%*RD ±0.005%*RD
Phase
(I ≥ 50mA)
Measuring Range 0~360° 0~360°
Minimum Resolution 0.000 1° 0.000 1°
Accuracy ±0.012° ±0.006°
 

4.4 Power / Electrical energy

Voltage range Current range Power factor Accuracy ±(% of reading) 
Class 0.05 Class 0.02
30 V ≤ U ≤ 480 V 50 mA ≤ I ≤120 A 0.5L~1~0.5C 0.05%*RD 0.02%*RD
10 mA ≤ I < 50 mA 1 0.05%*RD 0.02%*RD
0.04%*RD
0.5L~1~0.5C 0.08%*RD
3 mA ≤ I < 10 mA 1 0.08%*RD 0.04%*RD
0.5L~1~0.5C 0.15%*RD 0.08%*RD
0.2 mA ≤ I < 3 mA 1 0.08%*RD×3mA/I 0.04%*RD×3mA/I
  1. Output power stability: 0.02% / 2min (Class 0.05), 0.01% / 2min (Class 0.02)
  2. Power/electric energy Measuring range: The combination of AC voltage and current range
  3. Power factor Measuring range: -1.000 00…0.000 00…1.000 00;
  4. Standard electric energy pulse output: High frequency pulse output port outputs 60KHz at full range, low frequency pulse output port outputs 6Hz at full range;
  5. Standard electric energy pulse input: Frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V;
  6. Electric energy error display: Auto, resolution is 0.0001%.
 

4.5 Clock

  1. Daily reckoning error bounds: ±0.05 s/d 
 

5. General Specifications

Power supply AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
Warm up time 30 min
Temperature performance Storage temperature: 5°C~45°C
Operating temperature: -10°C~55°C  
Humidity performance Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R·H, non-condensing
Communication interface RS232, RS485, LAN
Dimensions of test bench
(L*W *table H / total H, mm)
Position number 3 positions 6 positions 12 positions 16 positions
Manual wiring 1350*800*750/1140 1950*800*750/1140 -- --
Manual connect 1350*750*750/1395 1850*750*750/1395 1830*750*610/1765 2350*750*610/1765
Dimensions of computer desk
(L*W*H, mm)
No Standard meter 1000*800*750
Standard meter 1500*800*750
 

6. Ordering Information

TD3600 Three-Phase Energy Meters Test Bench
Special Customized Function Selection Table
Tick Optional function Description
  Manual wiring The default option is Crimping wiring (with meter rack) , Manual wiring is optional.
  Harmonic output 2nd~21th harmonic
  Offering compatibility with both single-phase and three-phase Up to 12 test positions
  Current transformer Up to 12 test positions
  Standard meter Class 0.05 / 0.02
  Other requirements  

Company Profile
 

TD3600 Three-Phase Energy Meters Test Bench

TD3600 Three-Phase Energy Meters Test BenchTD3600 Three-Phase Energy Meters Test Bench

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours