- Overview
- Company Profile
Basic Info.
Model NO.
TD1220
Voltage Output
0~10 kV
Current Output
0~50 mA
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.03
DC resistance measurement
100 Ω~2 TΩ/10 TΩ
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000
Packaging & Delivery
Package Size
50.00cm * 50.00cm * 25.00cm
Package Gross Weight
18.000kg
Product Description
TD1220 Testing Apparatus for DC High Voltage and High Value Resistor
2. Features
4. Characteristics
1. Summary
TD1220 applied to calibrate DC high voltage high and high resistor, high voltage resistance case, DC high voltage meter, insulation resistance tester verification device (MOHM meter verification device) etc.2. Features
- DC high voltage output:0~10 kV
- DC small current output:0~50 mA
- DC resistance measurement:100 Ω~2 TΩ(10 TΩ option)
- Accuracy class:0.03
- Constant current source (CC) and constant voltage source (CV) modes
- CV mode: suitable for high resistance measurements
- CC mode: suitable for low resistance measurements
- Excellent electrical isolation and protection
- LCD touch screen.
- Setting output values by keys.
- Test software (option)
3. Applications
☆ Calibration for DC High Voltage / High Resistance Unit |
|
4. Characteristics
☆ CV/CC Mode to Measure DC Resistance |
|
☆ Statistical Analysis |
|
☆ Multiple Output Mode |
|
|
☆ Multiple Output Mode |
|
5. Specifications
5.1 DC Voltage/Current Output
Type | Range | Resolution | Stability ( % / min ) | Accuracy ±(ppm of reading + ppm of range) [1] | Max Burden |
DCV | 10 V | 100 μV | 0.01 | 120 + 80 | 50 mA |
100 V | 1 mV | 0.01 | 120 + 80 | 50 mA | |
1 kV | 10 mV | 0.01 | 120 + 80 | 50 mA | |
10kV | 100 mV | 0.01 | 200 + 100 | 3 mA | |
DCI | 3 mA | 10 nA | 0.01 | 120 +80 | 1000 V |
20 mA | 100 nA | 0.01 | 120 +80 | 1000 V | |
50 mA | 100 nA | 0.01 | 120 +80 | 1000 V | |
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). |
5.2 DC Resistance Measurement
Range ( Ω ) | Mode | Accuracy ±(%*reading + Ω )[2] |
100.000 ≤ R ≤ 1.000 00 k | CC / CV | 0.02 + 30 m |
1.000 00 k < R ≤ 10.000 0 k | CC / CV | 0.02 + 300 m |
10.000 0 k < R ≤ 100.000 k | CC / CV | 0.02 + 3 |
100.000 k < R ≤ 1.000 00 M | CC / CV | 0.03 + 30 |
1.000 00 M < R ≤ 10.000 0 M | CV | 0.05 + 300 |
10.000 0 M < R ≤ 100.000 M | CV | 0.05 + 3 k |
100.000 M < R ≤ 1.000 00 G | CV | 0.15 + 30 k |
1.000 00 G < R ≤ 10.000 0 G | CV | 0.2 + 300 k |
10.000 0 G < R ≤ 100.000 G | CV | 0.5 + 30 M |
100.000 G < R ≤ 1.000 00 T | CV | 1 + 500 M |
1.000 00 T < R ≤ 10.000 0 T[2] | CV | 2.0 + 5 G |
Notes::[2] 10T is option |
6. General Specifications
Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature Performance | Working temperature:0°C~45°C; Storage temperature:-20°C~70°C |
Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storage humidity:(20%~80%) R·H,non-condensing |
Interface | RS232 |