- Overview
- Company Profile
Basic Info.
Model NO.
TD1050
Power
Electricity
Voltage Output
20 mV ~ 1100 V
Current Output
10 mA~ 1050 A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05
DC current output
10 mA~ 1050 A, 2100 A optional
AC current output
10 mA ~ 1020 A, 2050 A is optional
DC voltage output(optional)
20 mV ~ 1100 V
AC voltage output(optional)
1 V ~ 825 V
Frequency
40 Hz ~ 400 Hz
DC resistance output(optional)
10 Ω ~ 110 MΩ
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000
Packaging & Delivery
Package Size
180.00cm * 200.00cm * 180.00cm
Package Gross Weight
90.000kg
Product Description
TD1050 Calibration Apparatus for Clamp Meters
1. Summary
TD1050 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.2. Features
Accuracy: Class 0.05
DC current: 10 mA ~ 1050 A(2100 A is optional)
AC current output: 10 mA ~ 1020 A(2050 A is optional)
DC voltage output(optional): 20 mV ~ 1100 V
AC voltage output(optional): 1 V ~ 825 V
Frequency: 40 Hz ~ 400 Hz
DC resistance output(optional): 10 Ω ~ 11 MΩ
Two thickness copper rings
AC/DC power output(optional)
3. Application
☆ Calibrate Clamp Meter by Single-turn Method |
DCI output: 10 mA~1050 A(2100 A is optional) ACI output: 10 mA~1020 A(2050 A is optional), 40 Hz ~ 400 Hz Calibrate ACDC clamp ammeters |
☆ Calibrate Clamp Power Meters(optional) |
|
☆Calibrate Multi-function Clamp Meters(optional) |
DCV output: 20 mV ~ 1100V ACV output: 1 V ~ 825 V, 40 Hz ~ 400 Hz RES output range: 10 Ω ~ 11 MΩ Calibrate AC/DC voltmeter and DC resistance meter |
4. Panel Features
Item | Description |
1 | Current Source, Output ACDC current. |
2 | Copper Ring 1, I≤110 A. |
3 | Copper Ring 2, I>100 A. |
4 | Workbench, used to settle the device. |
5 | Operate Panel, adjust electric parameter of the device. |
6 | Voltage Output terminals |
7 | Resistance Output terminals |
8 | Operate Panel terminal, connected to the control panel. |
9 | RS232 Interface,. |
10 | Power Switch |
11 | E-Stop, Used to stop the power supply in an emergency |
5. Characteristics
☆ Convenient Traceability |
|
☆ Wide Output Range |
6. Specifications
6.1 DC Current
Copper Ring | Range | Resolution | Output Range | Max Load |
Ring 1 | 100 mA | 1 μA | 10.000 mA ~ 110.000 mA | 8 V |
300 mA | 1 μA | 30.000 mA ~ 330.000 mA | 8 V | |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 8 V | |
3 A | 10 μA | 0.30000 A ~ 3.30000 A | 8 V | |
10 A | 100 μA | 1.0000 A ~ 11.0000 A | 8 V | |
30 A | 100 μA | 3.0000 A ~ 33.0000 A | 8 V | |
100 A | 1 mA | 10.000 A ~ 110.000 A | 8 V | |
Ring 2 | 250 A | 1 mA | 20.000 A ~ 275.000 A | 8 V |
500 A | 1 mA | 50.000 A ~ 550.000 A | 8 V | |
1000 A | 10 mA | 100.00 A ~ 1050.00 A | 8 V | |
2000 A [1] | 10 mA | 200.00 A ~ 2100.00 A | 8 V | |
Note[1]: 2000 A is Optional |
Range | Stability (±%/min) | Accuracy, ±(ppm*RD+ppm*RG) [2] | Ripple Factor (%) |
100 mA | 0.01 | 300 + 100 | <0.5 |
300 mA | 0.01 | 300 + 100 | < 0.5 |
1 A | 0.01 | 300 + 100 | < 0.5 |
3 A | 0.01 | 300 + 100 | < 0.5 |
10 A | 0.01 | 300 + 100 | < 0.5 |
30 A | 0.01 | 300 + 100 | < 0.5 |
100 A | 0.01 | 300 + 100 | < 0.5 |
250 A | 0.01 | 300 + 100 | < 0.5 |
500 A | 0.01 | 300 + 100 | < 0.5 |
1000 A | 0.01 | 300 + 100 | < 0.5 |
2000 A | 0.01 | 300 + 100 | < 0.5 |
Note[2]: RD=Reading,RG=Range, unless otherwise noted; |
- Output range: 10 mA ~ 1050 A2100 A
- Manual or automatic range switch.
- Adjustment fineness: 0.002%*RG
- 6 digits decimal display
- Protections: open-circuit protection, overload protection, over-heat protection
6.2 AC Current
Copper Ring | Range | Resolution | Output Range | Frequency | Max Compliance Voltage(rms) |
Ring 1 | 100 mA | 1 μA | 10.000 mA ~ 110.000 mA | 40 Hz ~ 400 Hz | 6 V |
300 mA | 1 μA | 30.000 mA ~ 330.000 mA | 40 Hz ~ 400 Hz | 6 V | |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 40 Hz ~ 400 Hz | 6 V | |
3 A | 10 μA | 0.30000 A ~ 3.30000 A | 40 Hz ~ 400 Hz | 6 V | |
10 A | 100 μA | 1.0000 A ~ 11.0000 A | 40 Hz ~ 400 Hz | 6 V | |
30 A | 100 μA | 3.0000 A ~ 33.0000 A | 40 Hz ~ 400 Hz | 6 V | |
100 A | 1 mA | 10.000 A ~ 110.000 A | 40 Hz ~ 400 Hz | 6 V | |
Ring 2 | 250 A | 1 mA | 20.000 A ~ 275.000 A | 40 Hz ~ 400 Hz | 6 V |
500 A | 1 mA | 50.000 A ~ 550.000 A | 40 Hz ~ 400 Hz | 6 V | |
1000 A | 10 mA | 100.00 A ~ 1020.00 A | 40 Hz ~ 400 Hz | 6 V | |
2000 A [3] | 10 mA | 200.00 A ~ 2050.00 A | 40 Hz ~ 400 Hz | 6 V |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Distortion (%) |
100 mA | 0.01 | 300 + 100 | <0.5 |
300 mA | 0.01 | 300 + 100 | <0.5 |
1 A | 0.01 | 300 + 100 | <0.5 |
3 A | 0.01 | 300 + 100 | <0.5 |
10 A | 0.01 | 300 + 100 | <0.5 |
30 A | 0.01 | 300 + 100 | <0.5 |
100 A | 0.01 | 300 + 100 | <0.5 |
250 A | 0.01 | 300 + 100 | <0.5 |
500 A | 0.01 | 300 + 100 | <0.5 |
1000 A | 0.01 | 300 + 100 | <0.5 |
2000 A [1] | 0.01 | 300 + 100 | <0.5 |
Note[3]: Range 2000 A is optional. |
- Output range: 10 mA ~ 1020 A (2050 A)
- Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz,accuracy ±0.01%.
- Adjustment fineness: 0.002%*RG
- 6 digits display
- Protections: open-circuit protection, overload protection, over-heat protection
6.3 DC Voltage(optional)
Range | Resolution | Output Range | Max Burden |
200 mV | 1 μV | 20.000 mV ~ 220.000 mV | 100 mA |
1 V | 10 μV | 0.10000 V ~ 1.00000 V | 100 mA |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 100 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 600 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 60 mA |
600 V | 1 mV | 60.000 V ~ 660.000 V | 25 mA |
1000 V | 10 mV | 100.00 V ~ 1100.00 V | 20 mA |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Ripple Factor (%) |
200 mV | 0.01 | 300 + 200 | <0.5 |
1 V | 0.01 | 300 + 200 | < 0.5 |
10 V | 0.01 | 300 + 200 | < 0.5 |
30 V | 0.01 | 300 + 200 | < 0.5 |
100 V | 0.01 | 300 + 200 | < 0.5 |
300 V | 0.01 | 300 + 200 | < 0.5 |
600 V | 0.01 | 300 + 200 | < 0.5 |
1000 V | 0.01 | 300 + 200 | < 0.5 |
- Output range: 20 mV ~ 1100 V
- Manual or automatic range switch
- Adjustment fineness: 0.002%*RG
- 6 digits display
- Protections: short-circuit protection, overload protection, over-heat protection
6.4 AC Voltage(optional)
Range | Resolution | Output Range | Frequency | Max Burden(rms) |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 40 Hz ~ 400 Hz | 800 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 40 Hz ~ 400 Hz | 700 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 40 Hz ~ 400 Hz | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 40 Hz ~ 400 Hz | 70 mA |
750 V | 1 mV | 75.000 V ~ 825.000 V | 40 Hz ~ 400 Hz | 30 mA |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Distortion Factor (%) |
10 V | 0.01 | 300 + 200 | <0.5 |
30 V | 0.01 | 300 + 200 | <0.5 |
100 V | 0.01 | 300 + 200 | <0.5 |
300 V | 0.01 | 300 + 200 | <0.5 |
750 V | 0.01 | 300 + 200 | <0.5 |
- Output range: 1 V ~ 825 V
- Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz, accuracy ±0.01%.
- Manual or automatic range switch
- Adjustment fineness: 0.002%*RG
- 6 digits display
- Protections: short-circuit protection, overload protection, over-heat protection
6.5 DC Resistance(optional)
Range | Resolution | Output Range | Accuracy ±(ppm*RD+ppm*RG) | Allowable Current |
100 Ω | 1 mΩ | 10.000 Ω ~ 110.000 Ω | 300 + 200 | 1 mA ~ 50 mA |
1 kΩ | 10 mΩ | 0.10000 kΩ ~ 1.10000 kΩ | 300 + 200 | 100 μA ~ 5 mA |
10 kΩ | 100 mΩ | 1.0000 kΩ ~ 11.0000 kΩ | 300 + 200 | 10 μA ~ 500 μA |
100 kΩ | 1 Ω | 10.000 kΩ ~ 110.000 kΩ | 300 + 200 | 10 μA ~ 50 μA |
1 MΩ | 10 Ω | 0.10000 MΩ ~ 1.10000 MΩ | 300 + 200 | 1 μA ~ 5 μA |
10 MΩ | 100 Ω | 1.0000 MΩ ~ 11.0000 MΩ | 600 + 400 | 100 nA ~ 500 nA |
- Output range: 10 Ω ~ 11 MΩ
- Manual or automatic range switch
- Adjustment fineness: 0.002%*RG
- 6 digits display
6.6 ACDC Power(optional)
Type | Current Range | Combination of Voltage and Current | Accuracy ±(%*Power Output)[1] [2] |
DC | 1000 A | (20 mV~1100 V) × (10 mA~1050 A) | 0.07~0.29 |
2000 A [3] | (20 mV~1100 V) × (10 mA~2100 A) | 0.07~0.29 | |
AC | 1000 A | (1 V~825 V) × (10 mA~1020 A) | 0.07~0.42 |
2000 A[3] | (1 V~825 V) × (10 mA~2050 A) | 0.07~0.42 | |
6.7 Phase and Power Factor(45 Hz~65 Hz)(optional)
Type | Range | Adjustment fineness | Accuracy[1] |
φ | 0.000°~359.999° | 0.005° | 0.1° |
λ | -1 … 0 … +1 | 0.0001 | 0.30% @ (λ=0.5) |
Note[1]: The accuracy formula of Power Factor: |
7. General Specifications
Power supply | AC (380±38)V,( 50 ± 2 ) Hz | |||||
Max Power Consumption | 16 kVA @ 1000 A Model,32 kVA @ 2000 A Model | |||||
Operating Condition | 0°C~40°C,(20%~85%) R·H,non-condensing | |||||
Storage Condition | -20°C~70°C,(10%~95%) R·H,non-condensing | |||||
Standard Interfaces | RS232×1 | |||||
Dimensions | Range | Width(W) | Depth(D) | Height(H) | Diameter of the copper ring | |
Ring 1(Ø1) | Ring 2(Ø2) | |||||
1000 A | 740 mm | 1723 mm | 1467 mm | 10 mm | 19 mm | |
2000 A | 1480 mm | 1723 mm | 1467 mm | 10 mm | 27 mm | |
8. Ordering information
Function | AC/DC Current Output ( ACI & DCI ) | AC/DC Voltage Output ( ACV & DCV ) | Resistance Output (Res ) | Power Output (Power) |
TD1050-X | ★ | - | - | - |
TD1050-X-M | ★ | ★ | ★ | ★ |