Basic Info.
Model NO.
TD1000
AC current output
20 mA ~ 1100 A
AC voltage output
1 V ~ 825 V
DC current output(optional)
20 mA ~ 22A
DC voltage output(optional)
20 mV ~ 1100V
DC resistance output
10 Ω ~ 11 MΩ
Transport Package
Package for Exporting
Specification
2310 mm (W)*750 mm (D) *1280 mm (H)
Trademark
TUNKIA
Origin
China
Production Capacity
1000
Product Description
TD1000 Calibration Apparatus for Clamp Meters
TD1000 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.
Accuracy: Class 0.05, Class 0.1 available
AC current output: 20 mA ~ 1100 A
AC voltage output: 1 V ~ 825 V
DC current output(optional): 20 mA ~ 22A
DC voltage output(optional): 20 mV ~ 1100V
DC resistance output: 10 Ω ~ 11 MΩ
Two thickness copper rings
Remote adjustment(optional)
☆ Calibrate AC Clamp Meter by Single-turn Method |
ACI output: 20 mA ~ 1100 A, 45 Hz ~ 65 Hz Two thickness copper rings. |
☆ Calibrate DC Clamp meters by Equivalent Ampere-turn Method(optional) |
DCI output: 20 mA ~ 22 A Coil: 50 T, accuracy ±0.3% Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters. |
☆ Calibrate Multi-function Clamp Meters |
ACV output: 1 V ~ 825 V, 45 Hz ~ 65 Hz DCV output: 20 mV ~ 1100V RES output: 10 Ω ~ 11 MΩ Calibrate AC/DC Voltmeters and DC Resistance Meters |
Item | Description |
1 | Current Source, Output ACDC current. |
2 | Copper Ring 1, I≤100 A(AC). |
3 | Copper Ring 2, I>100 A(AC). |
4 | 50T Coil, used to calibrate the DC Clamp meters by amplifing the DC current. |
5 | Wiring Panel, integrates the output terminals, power switchs and e-stop. |
6 | Operate Panel, adjust electric parameter of the device. |
7 | Workbench, Used to settle the device. |
☆ Convenient Traceability |
Calibrate the AC current source through accessing the standard ammeter(TH0630 Precision Through Core AC Ammeter)to the current loop. |
6.1 AC Current
Range | Resolution | Output Range | Frequency | Max Compliance Voltage(rms) |
200 mA | 1 μA | 10.000 mA ~ 110.000 mA | 45 Hz ~ 65 Hz | 50 V |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 45 Hz ~ 65 Hz | 15 V |
5 A | 10 μA | 0.50000 A ~ 5.50000 A | 45 Hz ~ 65 Hz | 8 V |
20 A | 100 μA | 2.0000 A ~ 22.0000 A | 45 Hz ~ 65 Hz | 2 V |
50 A | 100 μA | 5.0000 A ~ 55.0000 A | 45 Hz ~ 65 Hz | 1 V |
100 A | 1 mA | 10.000 A ~ 110.000 A | 45 Hz ~ 65 Hz | 0.7 V |
250 A | 1 mA | 25.000 A ~ 275.000 A | 45 Hz ~ 65 Hz | 0.7 V |
500 A | 1 mA | 50.000 A ~ 550.000 A | 45 Hz ~ 65 Hz | 0.7 V |
1000 A | 10 mA | 100.00 A ~ 1100.00 A | 45 Hz ~ 65 Hz | 0.7 V |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Distortion (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mA | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
1 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
5 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
20 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
50 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
100 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
250 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
500 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
1000 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
Note[1]: RD=Reading,RG=Range, unless otherwise noted; |
- Output range: 20 mA ~ 1100 A
- Adjustment fineness: 0.002%*RG,6 digits display
- Protections: open-circuit protection, overload protection, over-heat protection
6.2 AC Voltage
Range | Resolution | Output Range | Frequency | Max Burden(rms) |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 45 Hz ~ 65 Hz | 800 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 45 Hz ~ 65 Hz | 700 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 45 Hz ~ 65 Hz | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 45 Hz ~ 65 Hz | 70 mA |
750 V | 1 mV | 75.000 V ~ 825.000 V | 45 Hz ~ 65 Hz | 30 mA |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Distortion (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
10 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | <0.5 |
30 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
100 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
300 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
750 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
- Output range: 1 V ~ 825 V
- Adjustment fineness: 0.002%*RG
- 6 digits display
- Protections: short-circuit protection, overload protection, over-heat protection
Range | Resolution | Output Range | Max Compliance Voltage |
200 mA | 1 μA | 20.000 mA ~ 220.000 mA | 10 V |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 10 V |
5 A | 10 μA | 0.50000 A ~ 5.50000 A | 10 V |
20 A | 100 μA | 2.0000 A ~ 22.0000 A | 10 V |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) [2] | Ripple Factor (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mA | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
1 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
5 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
20 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
- Output range: 20 mA ~ 22 A(1000 At)
- Adjustment fineness: 0.002%*RG
- Display digits: 6 digits display
- Protections: open-circuit protection, overload protection, over-heat protection
6.4 DC Voltage(optional)
Range | Resolution | Output Range | Max Burden |
200 mV | 1 μV | 20.000 mV ~ 220.000 mV | 100 mA |
1 V | 10 μV | 0.10000 V ~ 1.00000 V | 100 mA |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 100 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 800 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 70 mA |
600 V | 1 mV | 60.000 V ~ 660.000 V | 25 mA |
1000 V | 10 mV | 100.00 V ~ 1100.00 V | 20 mA |
Range | Stability (±%/min) | Accuracy ±(ppm*RD+ppm*RG) | Ripple Factor (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mV | 0.01 | 0.02 | 300 + 200 | 600 + 400 | <0.5 |
1 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
10 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
30 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
100 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
300 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
600 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
1000 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
- Output range: 20 mV ~ 1100 V
- Adjustment fineness: 0.002%*RG
- 6 digits display
- Protections: short-circuit protection, overload protection, over-heat protection
6.5 DC Resistance
Range | Resolution | Output Range | Accuracy ±(ppm*RD+ppm*RG) | Allowable Current |
100 Ω | 1 mΩ | 10.000 Ω ~ 110.000 Ω | 600 + 400 | 1 mA ~ 15 mA |
1 kΩ | 10 mΩ | 0.10000 kΩ ~ 1.10000 kΩ | 600 + 400 | 100 μA ~ 1.5 mA |
10 kΩ | 100 mΩ | 1.0000 kΩ ~ 11.0000 kΩ | 600 + 400 | 10 μA ~ 150 μA |
100 kΩ | 1 Ω | 10.000 kΩ ~ 110.000 kΩ | 600 + 400 | 10 μA ~ 150 μA |
1 MΩ | 10 Ω | 0.10000 MΩ ~ 1.10000 MΩ | 600 + 400 | 1 μA ~ 15 μA |
10 MΩ | 100 Ω | 1.0000 MΩ ~ 11.0000 MΩ | 600 + 400 | 100 nA ~ 2 nA |
- Output range: 10 Ω ~ 11 MΩ
- Adjustment fineness: 0.002%*RG
- 6 digits display
Power Supply | AC (220±22) V,(50±2) Hz |
Max Power Consumption | 2.5 kVA |
Operating Condition | 0°C ~ 40°C,(20% ~ 85%) R·H,non-condensing |
Storage Condition | -20°C ~ 70°C,(10% ~ 95%) R·H,non-condensing |
Standard Interfaces | RS 232 |
Dimensions | 2310 mm (W)× 750 mm (D) × 1280 mm (H) |