Basic Info.
Model NO.
DGG28
Voltage
220V
Structure
Piston Pump
Usage
Air Driven
Material
Stainless Steel
Certificate
Ce RoHS
Boost Ratio
28:1
Transport Package
1 Set/Case by Plywood Case
Trademark
SUNCENTER
Origin
China
Production Capacity
500 Sets/Month
Product Description
Suncenter brand Model: 28:1 pressure ratio air driven hydraulic pump for pressure testing
We offer the most complete range of Air driven liquid pump models in the industry measured for:
Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.
SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator.
The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don't reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.
Applications include:
Key features include:
DGG Series Liquid Pumps(Single acting, single air drive head)
of water application. High quality seals, long service life available.
Technical specification
The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
DGGD Series Liquid Pumps(Double acting, single air drive head)
They are characterized by the same features as the DGG pumps single acting, single air drive head types,
but they have less pulsations and deliver approx. 50 % more flow.
Technical specification
The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
Suncenter DLS Series Pneumatic (Air driven) Liquid Booster System
Suncenter- DLS Series Pneumatic(Air driven) Hydraulic Power Packs
SUNCENTER- Hydraulic power packs(Liquid pump system) are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa.
As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.
The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure.
DLS-DGG series test bench Technical specification
DLS-M series test bench Technical specification
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime
We offer the most complete range of Air driven liquid pump models in the industry measured for:
- Capability of ultimate pressure, flow or output horsepower.
- Compatibility with a broad variety of liquids, such as oil, water and chemical applications.
Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.
SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator.
The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don't reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.
Applications include:
- Pressure testing
- Burst(Hydrostatic) testing
- Work holding/power clamping
- Jacking/lifting
- Valve actuator control
- Hydraulic cylinder actuation
- Press safety overload devices
- Roller tensioning
- Metering
- Precision lubrication and spraying
- Liquefied gas transfer
Key features include:
- Compressed Air driven - no electricity required (connect to normal air compressor)
- In order to extend the lifetime of the pump, the driving air pressure should
- No airline lubricator required
- Pressures to 640Mpa (6400 bar)
- Wide range of models with different ratios
- Built-in-cooling on most models
- Easy to install, operate and maintain
- Best price / performance ratio
- No heat, flame or spark risk and explosion proof
- Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
DGG Series Liquid Pumps(Single acting, single air drive head)
- DGG pumps have aluminum bodies and wetted materials of stainless steel or carbon steel ,which
of water application. High quality seals, long service life available.
Technical specification
Model | Pressure Boost Ratio | Driven air pressure PL | Formula to calculate outlet pressure | MAX Outlet Pressure(bar)* | Liquid inlet Connection | Liquid outlet Connection | MAX Flow (L/min) |
DGG6 | 6:1 | 2-8 bar | 6XPL | 48 | NPT1/2 | NPT1/2 | 29.91 |
DGG10 | 10:1 | 2-8 bar | 10XPL | 80 | NPT1/2 | NPT1/2 | 18.84 |
DGG16 | 16:1 | 2-8 bar | 16XPL | 128 | NPT1/2 | NPT1/2 | 12.42 |
DGG28 | 28:1 | 2-8 bar | 28XPL | 224 | NPT1/2 | NPT1/2 | 7.11 |
DGG40 | 40:1 | 2-8 bar | 40XPL | 320 | NPT1/2 | NPT1/2 | 4.89 |
DGG64 | 64:1 | 2-8 bar | 64XPL | 512 | NPT1/2 | NPT3/8 | 3.08 |
DGG80 | 80:1 | 2-8 bar | 80XPL | 640 | NPT1/2 | NPT3/8 | 2.44 |
DGG100 | 100:1 | 2-8 bar | 100XPL | 800 | NPT1/2 | NPT3/8 | 1.92 |
DGG130 | 130:1 | 2-8 bar | 130XPL | 1040 | NPT1/2 | M14X1.5 | 1.47 |
DGG175 | 175:1 | 2-8 bar | 175XPL | 1400 | NPT3/8 | M14X1.5 | 1.14 |
DGG255 | 255:1 | 2-8 bar | 255XPL | 2040 | NPT1/4 | M14X1.5 | 0.75 |
DGG400 | 400:1 | 2-8 bar | 400XPL | 3200 | NPT1/4 | M14X1.5 | 0.48 |
DGG510 | 510:1 | 2-8 bar | 510XPL | 4080 | NPT1/4 | M14X1.5 | 0.65 |
DGG800 | 800:1 | 2-8 bar | 800XPL | 6400 | NPT1/4 | M14X1.5 | 0.42 |
The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
DGGD Series Liquid Pumps(Double acting, single air drive head)
They are characterized by the same features as the DGG pumps single acting, single air drive head types,
but they have less pulsations and deliver approx. 50 % more flow.
Technical specification
Model | Pressure Boost Ratio | Driven air pressure PL | Formula to calculate outlet pressure | MAX Outlet Pressure(bar)* | Liquid inlet Connection | Liquid outlet Connection | MAX Flow (L/min)** |
DGGD4 | 4:1 | 2-8 bar | 4XPL | 32 | NPT1/2 | NPT1/2 | 70.00 |
DGGD6 | 6:1 | 2-8 bar | 6XPL | 48 | NPT1/2 | NPT1/2 | 48.60 |
DGGD10 | 10:1 | 2-8 bar | 10XPL | 80 | NPT1/2 | NPT1/2 | 30.61 |
DGGD16 | 16:1 | 2-8 bar | 16XPL | 128 | NPT1/2 | NPT1/2 | 19.73 |
DGGD28 | 28:1 | 2-8 bar | 28XPL | 224 | NPT1/2 | NPT1/2 | 11.30 |
DGGD40 | 40:1 | 2-8 bar | 40XPL | 320 | NPT1/2 | NPT3/8 | 7.69 |
DGGD64 | 64:1 | 2-8 bar | 64XPL | 512 | NPT1/2 | NPT3/8 | 4.94 |
DGGD80 | 80:1 | 2-8 bar | 80XPL | 640 | NPT1/2 | NPT3/8 | 3.96 |
DGGD100 | 100:1 | 2-8 bar | 100XPL | 800 | NPT1/2 | NPT3/8 | 3.13 |
DGGD130 | 130:1 | 2-8 bar | 130XPL | 1040 | NPT1/2 | M14*1.5 | 2.40 |
DGGD175 | 175:1 | 2-8 bar | 175XPL | 1400 | NPT3/8 | M14*1.5 | 1.81 |
DGGD255 | 255:1 | 2-8 bar | 255XPL | 2040 | NPT1/4 | M14*1.5 | 1.23 |
DGGD400 | 400:1 | 2-8 bar | 400XPL | 3200 | NPT1/4 | M14*1.5 | 0.79 |
The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
Suncenter DLS Series Pneumatic (Air driven) Liquid Booster System
Suncenter- DLS Series Pneumatic(Air driven) Hydraulic Power Packs
SUNCENTER- Hydraulic power packs(Liquid pump system) are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa.
As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.
The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure.
DLS-DGG series test bench Technical specification
Model | Pressure Ratio | Driven air pressure PL | Formula to calculate outlet pressure | MAX Outlet Pressure(bar)* | Driven air inlet port | High pressure Outlet port | MAX Flow (L/min)** |
DLS-DGGD4 | 4:1 | 3-8 bar | 4XPL | 32 | G 1/2 | NPT/ZG | 70.0 |
DLS-DGG6 | 6:1 | 3-8 bar | 6XPL | 48 | G 1/2 | NPT/ZG | 29.91 |
DLS-DGG10 | 10:1 | 3-8 bar | 10XPL | 80 | G 1/2 | NPT/ZG | 18.84 |
DLS-DGG16 | 16:1 | 3-8 bar | 16XPL | 128 | G 1/2 | NPT/ZG | 12.42 |
DLS-DGG28 | 28:1 | 3-8 bar | 28XPL | 224 | G 1/2 | NPT/ZG | 7.11 |
DLS-DGG40 | 40:1 | 3-8 bar | 40XPL | 320 | G 1/2 | NPT/ZG | 4.89 |
DLS-DGG64 | 64:1 | 3-8 bar | 64XPL | 512 | G 1/2 | NPT/ZG | 3.08 |
DLS-DGG80 | 80:1 | 3-8 bar | 80XPL | 640 | G 1/2 | NPT/ZG | 2.44 |
DLS-DGG100 | 100:1 | 3-8 bar | 100XPL | 800 | G 1/2 | NPT/ZG | 1.92 |
DLS-DGG130 | 130:1 | 3-8 bar | 130XPL | 1040 | G 1/2 | NPT/ZG | 1.47 |
DLS-DGG175 | 175:1 | 3-8 bar | 175XPL | 1400 | G 1/2 | NPT/ZG | 1.14 |
DLS-DGG255 | 255:1 | 3-8 bar | 255XPL | 2040 | G 1/2 | NPT/ZG | 0.75 |
DLS-DGG400 | 400:1 | 3-8 bar | 400XPL | 3200 | G 1/2 | NPT/ZG | 0.48 |
DLS-DGG510 | 510:1 | 3-8 bar | 510XPL | 4080 | G 1/2 | NPT/ZG | 0.65 |
DLS-DGG800 | 800:1 | 3-8 bar | 800XPL | 6400 | G 1/2 | NPT/ZG | 0.42 |
DLS-M series test bench Technical specification
Model | Pressure Boost Ratio | Driven air pressure PL | Formula to calculate outlet pressure | MAX Outlet Pressure(bar)* | Driven air inlet port | High pressure outlet port | MaxFlow rate(L/min)** |
DLS-DGM4 | 4:1 | 3-8 bar | 4XPL | 32 | G 1/2 | NPT/ZG | 15.36 |
DLS-DGM100 | 10:1 | 3-8 bar | 10XPL | 80 | G 1/2 | NPT/ZG | 7.15 |
DLS-DGM16 | 16:1 | 3-8 bar | 16XPL | 128 | G 1/2 | NPT/ZG | 4.59 |
DLS-DGM30 | 30:1 | 3-8 bar | 30XPL | 240 | G 1/2 | NPT/ZG | 2.53 |
DLS-DGM44 | 44:1 | 3-8 bar | 44XPL | 352 | G 1/2 | NPT/ZG | 1.41 |
DLS-DGM64 | 64:1 | 3-8 bar | 64XPL | 512 | G 1/2 | NPT/ZG | 0.95 |
DLS-DGM100 | 100:1 | 3-8 bar | 100XPL | 800 | G 1/2 | NPT/ZG | 0.64 |
DLS-DGM170 | 170:1 | 3-8 bar | 170XPL | 1360 | G 1/2 | NPT/ZG | 0.37 |
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime