- Overview
- Product Description
- Features
- Product Parameters
- Detailed Photos
Basic Info.
Model NO.
GF102
Keyword
Energy Meter Calibration Test Bench
Model
1 Phase Energy Meter Calibration Test Bench
GF102
Single Phase Energy Meter Testing Bench
Accuracy Class
0.05%, 0.1%
Frequency Output Adjustment Range
40Hz-70Hz
Harmonic Number
2-51times
Active Power Energy
0.05%Rg
Weight (Kg)
12
Relative Humidity
35%-85%
Harmonic Phase
0-359.99
Transport Package
Standard Export Wooden Box
Specification
455x440x150mm
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200sets/Month
Product Description
Single Phase Energy Meter Calibration Test Bench
GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.
Meter under testing: 1P2W
2Testing mode: active power, reactive power
Test 3pcs or 2pcs meter synchronously
Start testing and creep testing
Reference standard and power source integrated, easy to carry
Measuring mechanical meter and electric meter
Operating by manual keyboard or PC software
With keyboard shortcuts
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.
Meter under testing: 1P2W
2Testing mode: active power, reactive power
Test 3pcs or 2pcs meter synchronously
Start testing and creep testing
Reference standard and power source integrated, easy to carry
Measuring mechanical meter and electric meter
Operating by manual keyboard or PC software
With keyboard shortcuts
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | One Phase AC 100-265V, frequency 50/60Hz. |
AC Voltage Output | |
Range | 57.7V, 100V, 220V, 380V; max 500V |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.1% (Non-capacitive load) |
Output load | max 25VA |
Measuring accuracy | 0.05%RG |
AC Current Output | |
Range | 200mA, 1A, 5A, 20A, 100A; max 120A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.1% (Non-capacitive load) |
Output load | max 50VA |
Accuracy | 0.05%RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.05° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0. 0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V,10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 455x440x150 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to +40°C |
Relative humidity | 35%-85% |
(1)RG means range, the same as below; (2)RD means the setted harmonic content, harmonic can be a single output,also multiple output. |