Basic Info.
Product Description
40Hz-1kHz Portable AC/DC Three Phase Standard Power Source
Introduction
Technical parameters
1. AC output | |
Voltage scope: 0 - 600V Range: 25V, 50V, 110V, 200V, 400V, 600V Current scope: 0 ~ 24A | |
Rated current range: 0.1A,0.5A,1A,5A,10A,20A; Voltage current regulation range: 0~120%; Voltage current regulation fineness: 5×10-5; | |
Voltage current error ≤0.03%(Rd)±0.02%(full range),0.05 level; Voltage current output power: every rated range full scale 100% ≥ 20W | |
Output frequency: | Range: 45 Hz ~ 65 Hz Resolution: 0.001 Hz Accuracy: 0.01 Hz |
Output phase: | Range: 0 ~ 359.99° fineness: 0.010 Accuracy: 0.01° Output Harmonic: Orders: 2~51 orders Amplitude: 0~20% |
Each order phase position fineness: | 0.010·N(N is harmonic order number) |
Output Power | Output power scope: ranged current range and rated voltage range can be mixed arbitrarily. Accuracy: 0.1, 0.05 level within rated range (reactive power accuracy will be one level lower) Output waveform distortation: AC voltage current ≤0.3% |
Energy Meter measurement: | Integrated error: 0.1,0.05% FS (impulse output ≤90kHz, three phase rated vaule=60kHz) |
2. DC output | |
DC voltage range: | 75mV,1V,3V,7.5V,15V,30V, output capacitance: 100mA; 75V,150V,300V,600V,1000V, output capacitance: 40mA; |
DC current range: | 30uA,300uA,3mA,30mA,maximum output capacitance: 9VA; 300mA,0.5,1,2.5,5A ,10A ,20A maximum output capacitance 10VA; |
DC voltage, current regulation range: 0~120% FS, fineness: 5×10-5 | |
Rated Voltage range accuracy: | error ≤0.06%(Rd)±0.04%(full range), 0.1 level; error≤0.03%(Rd)±0.02%(full range), 0.05 level |
DC 75mV output (load≥200Ω) accuracy error≤0.12%(Rd)±0.08%(full range), 0.2 level error≤0.06%(Rd)±0.04%(full range), 0.1 level | |
3.Others: | |
Working power supply: | Single phase 220V±10%, 50Hz±5% |
Working environment: | temperature 20ºC±10ºC relative humidity≤85%RH |
Size and Weight: | 460*480*200mm, 18kg |
Company introduction
Service and Warranty
Service
* Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
* Ensure customer get the detailed information about the product in hand.
* Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
* Welcome customers visit.
* Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
* Focus on communication, actively communicate with users, take notes of user's questions and schedule, provide the necessary technical support.
* Move quick and efficient, professional on delivery, installation, debugging, training and others.
Features
1. Can be used to test errors and variance caused by voltage, current, waveform or power factor change, for a variety of metering instrument such as energy meter, voltmeter, ammeter, wattmeter, frequency meter, power factor meter, phase meter
2. Can generate distorted wave with 2~32 order harmonic, harmonic number, order, amplitude and phase position to base wave can be controlled by programs
3. Operational amplifier work frequency 40HZ~1kHz, good linearity, dual output protection, High fidelity output signal and high shock-proof ability
4. With RS232 and USB(optional) communication interface for PC connection
5. With aluminum alloy carrying box, which look nice, and with little weight