Basic Info.
Model NO.
CCL-C180
Reaction Time
15 Minutes
Sample Plate
60 Sample Positions
Transport Package
Standard Export Package
Specification
standard
Trademark
Comcernmed
Origin
China
Product Description
Medical Hospital lab equipment semi Auto biochemistry chemistry Analyzer
Model:CCL-C180
Technical parameters
Throughput | Constant 180T/h (non-ISE) | |
Theory | Absorption spectrometry, transmission turbidimetry | |
Methodology | End-point,Fixed-time,Kinetic,Ion selective electrode | |
Test according set up, random access | ||
Reaction plate | Contain 81 reaction cuvettes | |
Maximum reaction time | 15 minutes | |
Minimum reaction volume | 150 ul | |
Material of cuvettes | Special UV-transparent optical glass | |
Cuvettes use | Automatically cuvettes washing | |
Optical Unit | ||
Light Source | Halogen-tungsten lamp | |
Photometer | Reversed optics | |
Wavelength | 340nm-900nm wavelength option | |
Absorption | 0-4 Abs | |
Reagent Unit | ||
Reagent plate | 60 reagent positions,support for single and double reagent, reagent completely open | |
Reagent storage temperature | 2~10ºC | |
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml,dead volume is less than 1.0 ml | |
Reagent volume | 20-500 ul, step by 1.0 ul | |
Reagent/Sample Probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Sample Unit | ||
Sample plate | 60 sample positions | |
Sample type | Human (animal) serum,plasma,urine etc. | |
Samples cup | Support one-off micro cups | |
Sample volume | 2-100 ul, step by 0.1 ul | |
Sample/reagent probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Temperature control Unit | ||
Heating method | Direct thermal solid thermostat closed | |
Temperature equilibrium time | <3 minutes | |
Reaction temperature | 37±0.1ºC | |
Temperature fluctuation | ±0.1ºC | |
Operation Unit | ||
Software | WindowsXP,2000 | |
Database | SQL Server | |
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | |
Print format | Can be set up, offer several standard format | |
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | |
Quality control methods: | Real time, within day & between day | |
Quality control diagram | L-J,cumulative,twin plot | |
Status display | Real time monitoring of reagent residual volume. Running status of reagent tray, samples tray | |
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | |
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | |
Others | ||
Water consumption: < 6L/h | Power Supply: AC 220V±22V 50Hz±1Hz | |
Frequency: Maximum 600VA | Dimension:782mm×581mm×545mm | |
Net Weight: 60kg | Accessory: Software |
We CONCERNMED make one-stop shopping hospital medical equipment:
one-stop shopping hospital medical equipment | x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) | ||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |