- Overview
- Product Description
- Product Parameters
- Packaging & Shipping
- Company Profile
Basic Info.
Product Description
15" Multiparameter Portable Bed Side Patient Monitor
Features
* 15 inch high brightness (800x600) colorful TFT LCD
* Simultaneous display of 7 lead ECG waveform
* Indented menu layout to maximize the space for display
* Protection agasint defibrillation and ESU interference
* New SPO2 technology to assure precise measurement
* Precise SPO2 measurement for low prefusion & finger motion
* Analysis of real time ST segment arrhythmia
* Able to analyze 15 kinds of drug level
* 168 hour graphic and tabular trend with data storage
* High efficient power management without electric fan to avoid cross contamination
* Up to 66 beds for networking capacity to connect with HIS
* 750 group NIBP data for recall and display
*Standard configuration: ECG, NIBP, SpO2, PR, RESP., TEMP., HR,
*Optional configuration: 1/2/4 IBP, EtCO2, multi gas, CO, 12 lead ECG, thermal recorder, touch screen, WiFi, HDMI, USB, VGA, SunTech NIBP,Masimo SPO2 module
ECG
Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 3 channel
Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto
HR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1 bpm, whichever greater
Resolution: 1 bpm
Sensitivity: > 200 (uVp-p)
Differential Input Impedance: > 5 MΩ
CMRR: Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dB
Electrode offset Potential: ± 300 mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 seconds after defibrillation
ECG Signal Range: ±8 mV (Vp-p)
Bandwidth:Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mVp-p), accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mV
Alarm: Available
Review: Available
SpO2
Measurement Range: 0 ~ 100 %Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified
Actualization interval: about 1 second
Alarm Delay: 10 second
Pulse Rate Measurement and Alarm Range: 0 ~ 254 bpm
Resolution: 1 bpm
Accuracy: ± 2 bpm
NIBP
Method: OscillometricMode: Manual, Auto, STAT
Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes)
Measurement Period in STAT Mode: 5 minutes
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measurement and Alarm Range
Adult Mode: SYS: 40 ~ 270 mmHg, DIA: 10 ~ 215 mmHg, MEAN: 20 ~ 235 mmHg
Pediatric Mode: SYS: 40 ~ 200 mmHg, DIA: 10 ~ 150 mmHg, MEAN: 20 ~ 165 mmHg
Neonatal Mode: SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg
Resolution: Pressure: 1mmHg
Accuracy: Pressure
Maximum Mean error: ±5 mmHg
Maximum Standard deviation: ±8 mmHg
Overpressure Protection
Adult Mode: 297 ± 3 mmHg
Pediatric Mode: 240 ± 3 mmHg
Neonatal Mode: 147 ± 3 mmH
Respiration
Method: Impedance between R-F (RA-LL)Differential Input Impedance: >2.5 MΩ
Measurement Impedance Range: 0.3~5.0 Ω
Baseline Impedance Range: 0 - 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
Temperature
Channel: 1Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1 °C
Accuracy: ± 0.1 °C
Actualization interval: about 1 second
Average Time Constant: < 10 second
Product dimension & weight
Length×Width×Height: 353mm×324mm×176mm
Weight: 4.5 Kg
Package list:
1* PM-300A Plus Patient Monitor
1* ECG Cable(5 Lead)
1* ECG Electrodes
1* SpO2 Probe
1* NIBP Cuff
1* Temp Probe
1* Extension tube
1* Power Wire
1* Grounding cable
1* User manual
1* Warranty
1* Certificate of Qualification
Packing: 1pc/carton, size: 39*37*30cm