Intelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive Tester

Customization: Available
After-sales Service: Online
Warranty: 1 Year

Products Details

Basic Info.

Model NO.
KD-216S
Transport Package
Plywood Case
Specification
180MMX300MMX400MM
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

Intelligent path ranging breakpoint short circuit electric leakage line detector/Trolley cable fault comprehensive tester

Functional characteristics
1. Used to test various types of 380 v. 600 v, 10 kv35kv, 110 kv220kv. 380 kv voltage grade of copper aluminum core power cable, coaxial communication cable and all kinds of local cable fault, Such as cable full length, open circuit, short circuit, broken line, low resistance fault, high resistance fault, high resistance leakage, high and low impedance grounding, grounding fault, armor grounding fault, flashover discharge fault, poor grounding contact and cable path identification detection functions;
2. Can cooperate with high-voltage equipment to realize the traditional cable fault test of low-voltage pulse method, impact flashover method, three pulse method, multiple pulse method, speed measurement method.
3. All Chinese operation software and user interface, sub-menu and text prompts to achieve human-machine interaction
4. It should be used as a high-voltage pulse power source for the precise fixed-point instrument of acoustic and magnetic synchronization method and step voltage method.
5. The pulse capacitor should be a combined structure with a convertible capacity.
6, there should be DC output, single discharge, periodic discharge three high-voltage output modes.
7. The discharge device should be built-in and controlled by the relay, and the time interval of periodic discharge can be adjusted by the time relay on the operation panel.
8. With fault conversion function. By means of DC or pulse, the high resistance fault can be converted into a fault with relatively low fault resistance, and the resistance value of the gold attribute dead ground fault can be appropriately improved to facilitate the fault ranging and accurate fixed point.
9. The high-voltage test line should have only one coaxial cable, which can simplify the test wiring, reduce the difficulty of fault detection, and greatly improve the speed and success rate of fault detection.
10 In order to ensure the safety of equipment and human body, there should be grounding resistance detection and grounding protection functions. When the system is poorly grounded, the high voltage cannot be started. When the system is abnormal, the "emergency stop" button on the operation panel can quickly cut off the height
Voltage output and safe grounding.
11. Global waveform and local waveform synchronous display, easy to overall analysis and detail adjustment.
12. Any high-resistance fault presents the simplest waveform characteristics similar to low-voltage pulse short circuit fault, which is easy to interpret.
13, when using multiple pulse method test, the interface collects 8 real waveforms at the same time, which is easier to interpret and reduce test errors, and improve test accuracy.
14. Built-in power supply, can be used for a long time in the environment without power supply.
15. Small size, light weight, easy to use, high failure detection success rate and test accuracy.
16. Stable performance in any environment, does not crash, signal acquisition high-voltage protection measures are safe
17. Built-in storage/retrieval function, which can easily save or retrieve data and waveform for re-analysis.
18. The test signal provides a variety of pulse width, no test blind area.

Intelligent path ranging breakpoint short circuit electric leakage line detector/Trolley cable fault comprehensive tester

Sampling methods

low voltage pulse method, impact flashover method, three pulse method, multiple pulse method speed measurement method

Sampling rate

200 MHZ, 100 MHZ, 80 MHZ, 4 MHZ, 20MHZ, 10 MHZ Pulse width :0.05MS, 0.1MS, 0.2MS, 0.5MS, 1MS, 2MS, 8MS

Wave speed setting

cross-linked ethylene, polyvinyl chloride, oil-impregnated paper, non-dripping oil and unknown type self-set

Impact high pressure

35KV and below

Apply pressure cable

380 v, 600 v, 10 kv, 35 kv, 110 kv, 220 kv

test distance

<60KM

Blind area

≤0.5 M

Resolution

0.5M

Test accuracy

0.5M

Impact high voltage

0~8KV, 0~16KV, 0~32KV optional

High voltage partial voltage

voltage accuracy 1.5

built-in capacitance

8MF/32KV, 8MF/16KV, 2MF/32KV

The first gear 0~8000V

the capacity of the capacitor is 32uF

Second gear 0~16000V

The capacity value of the capacitor is 8uF

The third stage 0~32000V

The capacity value of the capacitor is 2uF

Discharge period adjustable

discharge period adjustable 0~99 seconds

discharge time adjustable

discharge time 1~99 seconds adjustable, generally set at 0.3 seconds

High voltage output mode

DC, single pulse, periodic pulse

Maximum energy storage

≤1024J

Impact time

automatic impact about 4 seconds, manual impact any control time

Impact power

2KVA

Working power supply

AC220V10%50HZ2HZ24

Operating temperature

-10°C~40°C

25

 

Working humidity

≤80%

altitude

≤1000 meters

Dimensions

534LX444WX805H

Weight

not more than 75KG


Intelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive TesterIntelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive TesterIntelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive TesterIntelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive TesterIntelligent Path Ranging Breakpoint Short Circuit Electric Leakage Line Detector/Trolley Cable Fault Comprehensive Tester