Heating Blocks Can Be Sing From Room Temperature to 120° C Dry Bath Incubator Continuous and Timed Operation Settings Heating Blocks for Dry Bath Incubators

Certification: CE, ISO, FDA
Power Input: 160W
Voltage: 100-240V

Products Details

Basic Info.

Model NO.
01-910x 01-9191 01-9192. etc
Functions
Heating
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

Dry Bath Incubator
Heating Blocks Can Be Sing From Room Temperature to 120° C Dry Bath Incubator Continuous and Timed Operation Settings Heating Blocks for Dry Bath Incubators
Characteristic

 
This classic dry bath incubator is ideal for molecular biology, histology, and environmental, industrial, and clinical laboratories, and for applications including melting and boiling point determinations, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations, and in-situ hybridizations.

Features

• A broad temperature range, from room temperature to 120°C

• Continuous and timed operation settings

• Over-temperature protection

• Various interchangeable heating blocks are available

 
Ordering Information
 
Catalogue No. Functions Voltage [VAC] Power [W]

Heating temperature range [°C]

Control accuracy [°C]

Maximum safe temperature [°C]

01-910X Heating 100-120/200-240 160 5 above room temp. - 120 ±0.5 140

 


Heating Blocks Can Be Sing From Room Temperature to 120° C Dry Bath Incubator Continuous and Timed Operation Settings Heating Blocks for Dry Bath Incubators1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 