Model NO.
GF112B
Accuracy
0.2%
Current
0~120A
Voltage
0~300V
Phase
0~360
Frequency
45~65Hz
Gf112b
Handheld Single-Phase Energy Meter Calibrator at W
Transport Package
Standard Export Carton
Specification
CE, GF112B, 0.2%
Trademark
GFUVE
Origin
Beijing, China
HS Code
9030849000
Production Capacity
2000units/Month
Product Description
GF112B Handheld Single-Phase Energy Meter Calibrator at Worksite
It is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Features and Functions of Meter testing equipment GF112B Handheld Single-Phase Energy Meter Calibrator at Worksite
Current clamp and meter combined together, colorful and touch-screen display;
One AAA Li-battery can continuously working 4 hours;
Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-100A;
Display all the measuring parameters in one screen;
Current clamp has automatic conpensation function, 0.2% class accuracy;
Current clamp has automatic calibration function;
Integration design of the meter and clamp;
16bit high accuracy AD switch 32 bit ARM processor core.
Automatically record and save 999 groups calibrate data;
Micro-multifunction optic sampler
Manual/automatic test inductive single phase meters;
Manual/automatic test electric single phase meters;
Measure virtual value of alternating voltage (15~300Vrms);
Measure virtual value of alternating current (50mA~100Arms);
Test parameters: Active power, phase angle of voltage and current, frequency and etc.
Automatic store testing data, and 999 group test results can be save.
Specifications
Measure Scope
Voltage: 15- 300V(r. M. S)
Current: 5mA- 100A(r. M. S)
Phase angle: 0- 359.99º
Frequency: 45-65Hz
(2) Accuracy of measurement
Voltage & current: Better than 0.2%
Phase angle: Better than 0.05 º
Frequency: Better than 0.005 Hz
Active power: Better than 0.5%
Active power energy: Better than 0.5%
(3)Working and Storage Environment
Working Environment
Temperature and Humidity: -10- +55degrees5%-85%RHD
Storage Environment
Temperature and Humidity: -25-+70degrees5%-95% RHD
(4) Dimension
215mm(L)´ 60mm(W)´ 30mm(T)
Aperture of current clamp: 20mm/φ 16mm
(5) Weight
Mains: 0.25kg
Appendix and bag: 0.3kg
(6) Batteries
http://guangfuhui.en.made-in-china.com
It is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Features and Functions of Meter testing equipment GF112B Handheld Single-Phase Energy Meter Calibrator at Worksite
Current clamp and meter combined together, colorful and touch-screen display;
One AAA Li-battery can continuously working 4 hours;
Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-100A;
Display all the measuring parameters in one screen;
Current clamp has automatic conpensation function, 0.2% class accuracy;
Current clamp has automatic calibration function;
Integration design of the meter and clamp;
16bit high accuracy AD switch 32 bit ARM processor core.
Automatically record and save 999 groups calibrate data;
Micro-multifunction optic sampler
Manual/automatic test inductive single phase meters;
Manual/automatic test electric single phase meters;
Measure virtual value of alternating voltage (15~300Vrms);
Measure virtual value of alternating current (50mA~100Arms);
Test parameters: Active power, phase angle of voltage and current, frequency and etc.
Automatic store testing data, and 999 group test results can be save.
Specifications
Measure Scope
Voltage: 15- 300V(r. M. S)
Current: 5mA- 100A(r. M. S)
Phase angle: 0- 359.99º
Frequency: 45-65Hz
(2) Accuracy of measurement
Voltage & current: Better than 0.2%
Phase angle: Better than 0.05 º
Frequency: Better than 0.005 Hz
Active power: Better than 0.5%
Active power energy: Better than 0.5%
(3)Working and Storage Environment
Working Environment
Temperature and Humidity: -10- +55degrees5%-85%RHD
Storage Environment
Temperature and Humidity: -25-+70degrees5%-95% RHD
(4) Dimension
215mm(L)´ 60mm(W)´ 30mm(T)
Aperture of current clamp: 20mm/φ 16mm
(5) Weight
Mains: 0.25kg
Appendix and bag: 0.3kg
(6) Batteries
Accuracy class | 0.2% |
Active power measurement accuracy | 0.2%, 0.5% |
Energy measurement accuracy | 0.2%, 0.5% |
Power supply | AAA type, Li rechargeable battery, 1800mAh, 3.6V it can work 20 hours continuously |
Warming-up time | <5 min |
Voltage measurement | |
---|---|
U Range | 0-300V |
Accuracy | 0.2% |
Current measurement | |
I Range | 1mA-120A |
Accuracy | 0.2% |
Phase measurement | |
Range | 0.00°-359.99° |
Resolution | 0.01° |
Accuracy | 0.05° |
Frequency measurement | |
Range | 45-65Hz |
Resolution | 0. 001Hz |
Accuracy | 0.005Hz |
Power Factor Measurement | |
Range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Accuracy | 0.002 |
Energy pulse output | |
Pulse constant | 25000 |
Energy Pulse Input | |
Input range of pulse constant | 1-25000 |
Pulse input level | 5V |
Function | |
Register test | Yes |
PC management software | Yes |
LCD | 2.8 inch touch TFT color LCD |
Data storage | 1000 sets |
Communication port | RS232 |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III |
Degree of protection | IP42 |
Declaration of conformity | CE & CNAS certified |
Working temperature | -10°C to 55°C |
Working humidity | 5%-85%RHD |
Storage temperature | -25°C to 70°C |
Storage humidity | 5%-95%RHD |