Fluke 725 Multifunction Process Calibrator for Temperature and Pressure Transmitters

Customization: Available
After-sales Service: Yes
Warranty: 1 Year

Products Details

Basic Info.

Model NO.
Fluke 725
Current Output
24mA
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Customized
Non-Customized
Product Name
Multifunction Process Calibrator
Model Number
Fluke 725
Source Functionsment Range
Voltage, Current, Resistance, Frequency, Temperatu
Ramps
Slow Ramp, Fast Ramp, 25% Step-Ramp
Voltage
24 V
Batteries
4 AA Alkaline Batteries
Operating Temperature
-10°c to +55°c
Storage Temperature
-20°c to 71°c
Sensitivity
1 V Peak-to-Peak-Minimum
Transport Package
One Piece/Box
Specification
130 x 236 x 61 mm
Trademark
Fluke
Origin
United States
HS Code
9030311000
Production Capacity
10000PCS/Year

Product Description


Original and new fluke 725 us multifunction process calibrator for sale

 

Fluke 725 Multifunction Process Calibrator for Temperature and Pressure TransmittersMeasure volts, mA, RTDs, thermocouples, frequency, and ohms Source/simulate volts, mA, RTDs, thermocouples, frequency, and ohms
Measure and source pressure using Fluke 700P series pressure modules
Dual display shows input and output Built in 24V loop power supply
Programmable step and ramp for automated testing Powered by 4 AA batteries (25 hours typical operation) Size/weight 7.9" x3.8" x 1.9"

With the Fluke 725 Multifunction Process Calibrator you can easily source and measure almost any process parameter and test almost any process device. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules.

From the moment you pick it up, the Fluke 725 is ready to perform as a powerful, yet easy-to-use field calibrator. Its simple controls, without menus, make operation easy and the backlit display provides better visibility in poor light. It features a small, streamline shape and a rugged, reliable design that make it ideal for standing up to harsh field conditions.

Versatile troubleshooting tool

Power transmitters during test using the loop supply with simultaneous mA measurement so you can test a transmitter out of circuit and better isolate problems. The 725 can also test a variety of fast pulsed RTD transmitters and PLCs (Programmable logic controllers), with pulses as short as 10 ms.

Source mA with simultaneous pressure measurement to conduct valve and I/P (Input current/Output pressure) tests in a single device. You can also test flow meters with frequency and CPM (counts per minute) functions and perform fast linearity tests with auto-step and auto-ramp features so you can quickly verify the mA signal at different output levels.


Specifications: Fluke 725 Multifunction Process Calibrator

Measurement Accuracy
Voltage DC 30.000 V 0.02% + 2 counts (upper display)
30.000 V 0.02% + 2 counts (lower display)
100.00 mV 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency 2.0 to 1000.0 CPM 0.05% + 1 count
1.0 to 1100.0 Hz 0.05% + 1 count
1.00 to 10.00 kHz 0.05% + 1 count
Sensitivity 1 V peak-to-peak-minimum
Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC 100.00 mV 0.02% + 2 counts
10.000 V 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (source) 0.02% + 2 counts
24.000 mA (simulate) 0.02% + 2 counts
Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency 2.0 to 1000.0 CPM 0.05%
1.0 to 1100.0 Hz 0.05%
1.00 to 10.00 kHz 0.25%
Waveform 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.8°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK 0.6°C
BP 1.2°C
Source accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
Accuracy stated for 4-wire measurement.
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.4°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK 0.6°C
BP 1.2°C
Specifications
Ramp functions Source functions Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp
Loop power function Voltage 24 V
Accuracy 10%
Maximum current 22 mA, short circuit protected
Step functions Source functions Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range
Environmental Specifications
Operating temperature -10°C to +55°C
Storage temperature -20°C to 71°C
Operating altitude 3000 m
Safety Specifications
Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical and General Specifications
Size 130 x 236 x 61 mm
Weight 0.65 kg
Batteries 4 AA alkaline batteries
Battery replacement Separate battery compartment, accessable without breaking calibration seal
Side port connections Pressure module connector, also used for remote real-time programming

Fluke 725 Multifunction Process Calibrator for Temperature and Pressure Transmitters


Fluke 725 Multifunction Process Calibrator for Temperature and Pressure Transmitters
Fluke 725 Multifunction Process Calibrator for Temperature and Pressure Transmitters
FAQ

1.   Where is your company?

we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.

2.  How about the MOQ?

1 unit is ok.

3.  Shipping methods and lead time?

By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).

By Air: 7-10 working days to your airport.

By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days).
 

4.  What is the term of Payment?

T/T, L/C,Western Union, Paypal;  

30% T/T in advance,70% before delivery.
 

5.  What are your main products?