- Overview
- Product Parameters
- Packaging & Shipping
Basic Info.
Model NO.
707
Current Output
24 Ma
Thermocouple (TC)
T
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
LED
Customized
Customized
Model
707
Current MeasurementTrange
0 to 24 Ma
Loop Power
While Measuring Ma, 24 V
Voltage MeasurementTrange
0 to 28 V DC
Operating Temperature
-10 to 55°c
Safety
CSA C22.2 No. 1010.1:1992
Size
152 X 70 X 41 mm
Batteries
One 9V Battery Alkaline
Transport Package
UPS/DHL/FedEx
Specification
152 x 70 x 41 mm
Trademark
FLUKE
Origin
China
HS Code
9030899090
Production Capacity
50, 000 Pieces/Year
Product Description
Loop calibrator is ideal for calibration, repair and maintenance of current loops.
Fluke 707 Loop Calibrator with Quick Click Knob, .015% Accuracy
- High performance loop calibrator for calibration, repair, and maintenance
- Features large display and simple, quick-click interface for easy one-handed operation.
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.015%
- Provides 1 µA resolution for mA source, simulate, and measure
Fluke 707 - Loop Calibrator
High performance loop calibrator for calibration, repair, and maintenance Features large display and simple, quick-click interface for easy one-handed operation. Provides simultaneous mA and % readout for quick, easy interpretation of readings. Delivers mA accuracy of 0.015% Provides 1 µA resolution for mA source, simulate, and measureCurrent Measurement Range: 0 to 24 mA, Resolution: 0.001 mA, Accuracy: 0.015% Rdg + 2 LSD Current Sourcing Range: 0 to 20 mA or 4 to 20 mA, Accuracy: 0.015% Rdg + 2 LSD, Drive Capability: 1200 Ω; 950 Ω at 20 mA in HART mode Current Simulation Range: 0 to 20 mA or 4 to 20 mA, Accuracy: 0.015% Rdg + 2 LSD, Ext. loop voltage requirement: 12-30 V Loop Power While measuring mA, 24 V Voltage measurement Range: 0 to 28 V DC, Resolution: 1 mV, Accuracy: 0.015% Rdg + 2 LSD Operating Temperature -10 to 55°C Humidity (Without Condensation) 0 to 90% (0 to 35°C); 0 to 70% (35 to 55°C) Temperature Coefficient -10 to 18°C, 28 to 55°C, ±.005% of range per °C Safety CSA C22.2 No. 1010.1:1992 EMC EN50082-1:1992 and EN55022:1994 Class B Max. Voltage 30V (protection circuit for 230V) Size 152 x 70 x 41 mm Weight 224 g (340 g including holster) Batteries One 9V battery Alkaline What's included with the Fluke 707
- Fluke 707 Loop Calibrator
- Fluke AC72 Alligator Clips
- Fluke TL75 safety-designed test lead set
- Fluke C10 protective yellow holster with Flex-Stand™
- Instruction sheet