- Overview
- Product Description
- Features
- Product Parameters
Basic Info.
Model NO.
GF312D1
Application
Handheld Three Phase Energy Meter Calibrator
100A Clamp on CT
3PCS
Optical Sensor
1PC
Portable Box
Yes
Voltage Range
0-480V
Current Range
0-12A, 0-120A
LCD
6.4 Inch Color
Transport Package
Standard Carton Packaging
Specification
GF312D1 0.05%, 0.1%
Trademark
GFUVE
Origin
Beijing, China
HS Code
9030849000
Production Capacity
500sets/Month
Packaging & Delivery
Package Size
60.00cm * 40.00cm * 35.00cm
Package Gross Weight
20.000kg
Product Description
GF312D1 HANDHELD THREE PHASE ENERGY METER CALIBRATOR
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
- Three phase active or reactive electricity energy meter.
- Calibrate three phase, single phase, and active or reactive meter error.
- Measure U(voltage) of three phase or single phase.
- Measure I(current) of three phase or single phase.
- Measure active power of three phase or single phase.
- Measure reactive power of three phase or single phase.
- Measure apparent power of three phase or single phase.
- Measure power factor of three phase or single phase.
- Measure phase angle between voltage and current.
- Measure frequency of power line.
- Display vector diagram.
- Display waveform of U and I.
- Analyze and display content of harmonic of U and I.
- Measure 2-64 harmonic of U, I.
- Store and display measured data.
- Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
- Measure CT variable ratio.
- Measure the ratio or lag-angle of low-voltage transformer.
- Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
- Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
- Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Resolution | 6"TFT (640×480) |
Power supply | 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz |
Communication port | RS232 |
Test voltage | |
Range | 0-480V |
Error | ±0.05% (30V-480V) ±0.1% (5V-30V) |
Harmonic | 2nd-64st |
Test current | |
Range (direct connection) | 5mA-20A |
Error (direct connection) | ±0.05% (100mA-20A) ±0.1% (10mA-100mA) |
Range (clamp CT) | 10mA-3000A |
Error (camp CT) | ±0.2% (100mA-100A) ±0.5% (100A-3000A) |
Harmonic | 2nd-64st |
Power measure error | |
Active power (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) |
Reactive power (direct connection) | ±0.1% (0.1A-20A) |
Energy measure error | |
Active energy (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) |
Reactive energy (direct connection) | ±0.1% (0.1A-20A) |
Phase angle | |
Range | 0°-360° |
Resolution | 0.01o |
Error | ±0.05° |
Frequency | |
Range | 45-65Hz |
Resolution | 0.001Hz |
Error | 0.002Hz |
Pulse input | |
Input channel | 2 |
Input level | 5-24V |
Input frequency | Max. 2MHz |
Pulse output | |
Energy constant | 180000imp/kWh, 1800imp/kWh, 180imp/kWh |
Pulse ratio | 1:1 |
Output level | 5V |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Communication with PC | Yes |
Mechanical parameters | |
Instrument dimensions (W×H×D) (mm) | 245×162×60 |
Instrument Weight (kg) | 1.8 |
Carry case dimensions (W×H×D) (mm) | 450×320×185 |
Carry case (kg) | 10.6 |
Environmental conditions | |
Ambient temperature | -10°C to 55°C |
Relative humidity | 15%-85% |