Basic Info.
Model NO.
CWM-301D
Transport Package
Standard Export Packing
Specification
70*85*140cm
Trademark
CW
Origin
China
HS Code
90189070
Production Capacity
5000PCS/Year
Product Description
Extraordinary performance points
* Integrated breathing circuit with APL valve, excellent tightness.
* Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
* Applied with 2 high-precision vaporizers. (Selectatec).
* 10.1 inch touch screen with no dead space.
* Real-time detection for loops, Paw, BPM, VT and compliance.
* Comprehensive monitoring capabilities include ventilation parameters monitoring,preset parameters, alarm indication
and breathing waveform monitoring.
* Head light.
* Altitude compensation function.
* ACGO available to connect with T/Bain circuit for open operation.
* Yoke system with up to 3 back up cylinders (A type with 11 L size)(Optional)
Specifications
Certificates
Workshops
Exhibitions
* Integrated breathing circuit with APL valve, excellent tightness.
* Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
* Applied with 2 high-precision vaporizers. (Selectatec).
* 10.1 inch touch screen with no dead space.
* Real-time detection for loops, Paw, BPM, VT and compliance.
* Comprehensive monitoring capabilities include ventilation parameters monitoring,preset parameters, alarm indication
and breathing waveform monitoring.
* Head light.
* Altitude compensation function.
* ACGO available to connect with T/Bain circuit for open operation.
* Yoke system with up to 3 back up cylinders (A type with 11 L size)(Optional)
Specifications
Physical Specifications | |
Dimensions | 70*85*140cm |
Weight | 65kg |
Casters | Front wheels with lock |
Screen | 10.1 inch LCD / Touch screen |
Working Specifications | |
Power | AC 100V-240v,50Hz+2% |
Pipeline Supply | |
Gas configuration | O2, N2O,Air |
Pipeline input range | 280-600kPa |
Battery Power | |
Run-time | ≥180 mins |
Pre-setting Functions | |
Language | English |
Calibration | Automatic |
Applications | |
Patient range | Audlt/ Pediatric |
Modes of Ventilation | VCV, A/C, SIMV, MANUAL, PCV, PSV, STAND-BY |
Ventilator Parameter | |
Working type | Electronically controlled, pneumatic driven |
Tidal Volume range | 20-1500ml |
Pressure range | 5-60 cmH2O |
Respiration rate range | 1-100 bpm (1-40bpm under SIMV) |
l:E range | 4:1-1:8 |
Ptrigger range | -20-20 cmH2O (based on PEEP) |
Flow trigger | 0-15L |
Minute volume range | >18L/Min |
SIGH range | 0-5/100 |
System Standard | |
Hypoxic guard system | N2O cut-off valve, O2 concentration >25% |
Safety valve | <12.5kPa |
Fresh gas compensation | 25-75L/min |
Volume of CO2 absorber | 2L |
Flow meter | 5 tubes, Cascade 0.1-15L/min O2 |
0.1-15L/min N20.0.1-15L/min air | |
Vaporizer | 2 Selectetac, maximum 2 mounts(lsoflurane/Enflurane/Sevoflurane/Halothane) |
Monitoring | |
Display graphics | Waveforms of P-T, F-T, V-T, loops of P-VV-FF-P |
Types | VTi,VTe,MV.PmaxPplateau,RiCs,Freq,FiO2, ETCO2 (Optional). |
Alarm Limits | |
Audio/Visual | No tidal volume, MVPaw, FiOz limitation O2. |
Air failure, AC power failure, Battery low | |
PEEP | |
Type | Integrated, Electronic control |
Range | OFF3-30cmH0 |
Optional | AGSS, Suction Unit,Communication Interface |
Certificates