Basic Info.
Model NO.
CWM 301D
HS Code
9018907010
Production Capacity
5000PCS/Year
Product Description
301D Anesthesia System
Features:
Technique Specifications
Physical Specifications
Dimensions: 70*85*140cm
Weight: 65kg
Casters: Front wheels with lock
Screen: 10.1 inch LCD
Pipeline Supply
Gas configuration: O2,N2O,Air
Pipeline input range: 280-600Kpa
Battery Power
Run-time: ≥180 mins
Pre-setting Functions
Language: English
Calibration: Automatic
Ventilator Specifications
Modes of Ventilation
VCV: Volume Controlled Ventilation
A/C: Assist/Control Ventilation
SIMV: Manual
PCV: Pressure Control Ventilation
PSV: Pressure Support Ventilation
Ventilator Parameter
Working type: Electronic control, pneumatic driven
Tidal Volume range: 20-1500ml
Pressure range: 5-60cmH2O
Rispriation rate range: 1-100bpm(1-40bpm under SIMV)
I:E range: 4:1-1:8
Ptrigger range: >18L/Min
SIGH range: 0-5/100
System Standard
Hypoxic guard system: N2O cut-off Valve, O2 concentration>25%
Safety valve:<12.5Kpa
Fresh gas compensation: 25-75L/min
Volume of CO2 absorber: 2L
Flow meter: 5 tubes, Cascade 0.1-15L/min O2; 0.1-15L/min N2O,0.1-15L/min air
Vaporizer: 2 Selectetac, maximum 2 mounts (Isoflurane/Enflurane/Sevoflurane/Halothane)
Monitoring
Display graphics: Waveforms of P-T, F-T,V-T, loops of P-V, V-F, F-P
Types: VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform, FiO2
Alarm Limits
Audio/Visual: No tidal volume, MV, Paw, Fio2 limitation O2,Air failure, AC power failure, Battery low.
PEEP
Type: Integrated, Electronic control
Range: OFF, 3-30cmH2O
Optional
AGSS
Suction Unit
Communication Interface
Features:
- Integrated breathing circuit with APL valve, excellent tightness.
- Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
- Applied with 2 high-precision vaporizers. (Selectatec).
- 10.1 inch screen with no dead space.
- Real-time detection for loops, Paw, BPM, VT and compliance.
- Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
- Head light.
- Altitude compensation function.
- ACGO available to connect with T/Bain circuit for open operation.
- Yoke system with up to 3 back up cylinders (A type with 11L size) (Optional).
Technique Specifications
Physical Specifications
Dimensions: 70*85*140cm
Weight: 65kg
Casters: Front wheels with lock
Screen: 10.1 inch LCD
Pipeline Supply
Gas configuration: O2,N2O,Air
Pipeline input range: 280-600Kpa
Battery Power
Run-time: ≥180 mins
Pre-setting Functions
Language: English
Calibration: Automatic
Ventilator Specifications
Modes of Ventilation
VCV: Volume Controlled Ventilation
A/C: Assist/Control Ventilation
SIMV: Manual
PCV: Pressure Control Ventilation
PSV: Pressure Support Ventilation
Ventilator Parameter
Working type: Electronic control, pneumatic driven
Tidal Volume range: 20-1500ml
Pressure range: 5-60cmH2O
Rispriation rate range: 1-100bpm(1-40bpm under SIMV)
I:E range: 4:1-1:8
Ptrigger range: >18L/Min
SIGH range: 0-5/100
System Standard
Hypoxic guard system: N2O cut-off Valve, O2 concentration>25%
Safety valve:<12.5Kpa
Fresh gas compensation: 25-75L/min
Volume of CO2 absorber: 2L
Flow meter: 5 tubes, Cascade 0.1-15L/min O2; 0.1-15L/min N2O,0.1-15L/min air
Vaporizer: 2 Selectetac, maximum 2 mounts (Isoflurane/Enflurane/Sevoflurane/Halothane)
Monitoring
Display graphics: Waveforms of P-T, F-T,V-T, loops of P-V, V-F, F-P
Types: VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform, FiO2
Alarm Limits
Audio/Visual: No tidal volume, MV, Paw, Fio2 limitation O2,Air failure, AC power failure, Battery low.
PEEP
Type: Integrated, Electronic control
Range: OFF, 3-30cmH2O
Optional
AGSS
Suction Unit
Communication Interface