Basic Info.
Model NO.
BX-350
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month
Product Description
BX-350 Infrared Fast Calibrator/Infrared Blackbody Furnace Calibration Machine
BX-350 parameters:
[Introduction]
BX-350 Portable Infrared Calibrator (Blackbody Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has 2 types of power supply to choose from, one is AC220V and the other is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged
[feature]
Small and compact design, can calibrate infrared temperature to 350 ºC, large 2.25 inches (57mm) black body
Accuracy: Ambient operating temperature is 5-35 ° C (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.5 ° C; 50 ° C <temperature≤100 ° C (± 1.2ºF; 122ºF<temperature≤212ºF)
± 1.0 ºC; 100 ºC < temperature≤200 ºC (± 2.0 ºF; 212 ºF < temperature≤392 ºF)
± 1.5 ºC; 200 ºC < temperature≤350 ºC (± 3.0 ºF; 392 ºF < temperature≤662 ºF)
Stability: Ambient operating temperature is 5-35 ºC (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.1 ºC; 50 ºC <temperature≤100 ºC (± 0.2 ºF; 122 ºF <temperature≤212 ºF)
± 0.2 ºC; 100 ºC < temperature≤200 ºC (± 0.4 ºF; 212 ºF < temperature≤392 ºF)
± 0.3 ºC; 200 ºC < temperature≤350 ºC (± 0.6 ºF; 392 ºF < temperature≤662 ºF)
[Technical Index]
Range: 50 ° C-350 ° C (122 ° F-662 ° F)
Target emissivity: fixed at 0.95
Resolution: 0.1 ºC / 0.1 ºF
Heating time: 30 minutes to the maximum temperature
Cooling time: 40 minutes to 100 ° C (122 ° F)
Target diameter: 57mm
Power supply: 220VAC (± 10%), 1.25A / 110VAC (± 10%), 2.5
Dimensions: 180 × 114 × 233mm
Weight: 3kg
BX-350 Infrared Fast Calibrator/Infrared Blackbody Furnace Calibration Machine
X-500 parameters:
[Introduction]
BX-500 Portable Infrared Calibrator (Black Body Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has two kinds of power supply to choose from, one is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged.
[feature]
1. Small and compact design,
2. Calibrate infrared high temperature to 550 ºC,
3. Hit a 2.25 inch (57mm) black body target.
Accuracy
Ambient operating temperature: 5-35 ° C (41 ~ 95 ° F), relative humidity: 15 ~ 80%, air pressure: 75kPa ~ 106kPa
± 0.8 ºC; 50 ºC <temperature≤100 ºC (± 1.6 ºF; 122 ºF <temperature≤212 ºF)
± 1.6 ° C; 100 ° C <temperature≤200 ° C (± 3.2 ° F; 212 ° F <temperature≤392 ° F)
± 2.8 ° C; 200 ° C <temperature≤500 ° C (± 5.6 ° F; 392 ° F <temperature≤932 ° F)
stability
The ambient operating temperature is between 5 and 35 ° C (41 to 95 ° F), the relative humidity is 15 to 80%, and the air pressure is 75 kPa to 106 kPa
± 0.1 ° C; 50 ° C <temperature≤100 ° C (± 0.2 ° F; 122 ° F <temperature≤212 ° F)
± 0.2 ° C; 100 ° C <temperature≤200 ° C (± 0.4 ° F; 212 ° F <temperature≤392 ° F)
± 0.4 ° C; 200 ° C <temperature≤500 ° C (± 0.8 ° F; 392 ° F <temperature≤932 ° F)
[Technical Index]
Range: 50 ° C-500 ° C (122 ° F-932 ° F)
Target emissivity: fixed at 0.95
Resolution: 0.1 ºC / 0.1 ºF
Heating time: 40 to maximum temperature
Cooling time: 45 minutes to 100 ° C (122 ° F)
Target diameter: 57mm
Power supply: 220VAC (± 10%), 1.25A / 110VAC (± 10%), 2.5
Dimensions: 180 × 114 × 233mm
Weight: 3kg
BX-350 | BX-500 | |
Calibration temperature range | 50-350ºC | 50-500ºC |
Basic accuracy | ±0.5ºC(100ºC) | ±0.5ºC(100ºC) |
±1.2ºC(350ºC) | ±1.8ºC(500ºC) | |
Stability rate | ±0.1ºC(100ºC) | ±0.1ºC(100ºC) |
±0.2ºC(350ºC) | ±0.3ºC(500ºC) | |
heating time | 30 minutes to maximum temperature | 40 minutes to maximum temperature |
Cooling time | 30 minutes to 100 ºC | 45 minutes to 100 ºC |
Resolution | 0.1ºC | |
Target diameter | 57mm (2.25 inches) | |
Target emissivity | Fixed 0.95 | |
power supply | AC 230v (± 10) 1.5A; or AC 110v3A | |
size | 181 * 114 * 233mm | |
weight | 2682g |