Basic Info.
Model NO.
HMQA
Control
Computer Control
Power Source
AC220V
in-Phase Component
0.0001~200.0
Resolution Ratio
0.0001
Orthogonal Component (Sub)
0.001~700.0
Impedance
0.0001~20.0
Admittance
0.0001~20.0
Current
(1%-149%)in (in=5A)
Current Working Load
to to Tx<0.12,Cosφ=1.0
Power Frequency
50Hz±0.5Hz
Supply Voltage
220V±5V
Temperature
5ºC~40ºC
Relative Humidity
<80%
Standard
IEC
Certificate
CE, ISO, SGS
Warranty
1 Year
Transport Package
Wooden Box with Foam Inside
Specification
customize
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9031809090
Production Capacity
100 Set Per Month
Product Description
Automatic integrated CT current transformer tester bench equipment machine
I.Summary
Extreme speed CT Testing bench is a new generation transformer verification device developed by our company in order to adapt to the rapid and accurate characteristics of modern transformer verification. By HMQA-C extreme speed CT calibrator, current load box, control cabinet, current transformer special test table and other parts. On the premise of maintaining the characteristics of the original technology, the rapid measurement of the current transformer, the rapid positioning of the test point, the load box and the cover of the transformer with various ratios have been greatly improved
II. Product Functions
1.The device adopts the technology of voltage regulator to make the location of point more fast and accurate
2.The device has a qualitative improvement in the measuring speed of multiple current transformers, and can measure 12 current transformers with any ratio in 3-5 minutes.
3.The device is equipped with 5 A standard current transformer, the current load box is equipped with 5 A load value 2.5 VA-60VA, the voltage load box is equipped with 100 load values from 1.25 VA-158.75VA which can basically meet the requirements of users. Load box can switch automatically when measuring
4.The device can be used to measure the specification and non-specification of the transformer, and the user can specify the measurement of any percentage point when measuring
5.it has the interface to print different test report, and also can export test date
Those functions as below are optional based on actual testing requirements, and if require any extra functions, we have professional engineer service you .
III. Main Parameter:
1.Environment condition :
Temperature:5ºC~40ºC
Relative humidity:<80%(25ºC)
height above sea level <2500m
power frequency 50Hz±0.5Hz
supply voltage 220V±5V
2. Measuring range
in-phase component(%) : 0.0001~200. resolution ratio: 0.0001
Orthogonal Component (sub) 0.001~700.0 resolution ratio:0.001
impedance(Ω) : 0.0001~20.0 resolution ratio: 0.0001
admittance (ms) 0.0001~20.0 resolution ratio 0.0001
3.Intrinsic error
in phase component :ΔX=±(X×2%+Y×2%±2 character)
quadrature component :ΔY=±(Y×2%+±X×2%×34.38)±5 character
"X","Y"--Display value of instrument
"5 Words "-- Quantification Error of Instrument
Dial indicator :1 class
4.Scope of work:
current (1%-149%)In (In=5A)
(5%-149%)In (In=1A)
working load: current :To to Tx<0.12W cosφ=1.0
V. Service on-site
VI..Related products.
Extreme speed CT Testing bench is a new generation transformer verification device developed by our company in order to adapt to the rapid and accurate characteristics of modern transformer verification. By HMQA-C extreme speed CT calibrator, current load box, control cabinet, current transformer special test table and other parts. On the premise of maintaining the characteristics of the original technology, the rapid measurement of the current transformer, the rapid positioning of the test point, the load box and the cover of the transformer with various ratios have been greatly improved
II. Product Functions
1.The device adopts the technology of voltage regulator to make the location of point more fast and accurate
2.The device has a qualitative improvement in the measuring speed of multiple current transformers, and can measure 12 current transformers with any ratio in 3-5 minutes.
3.The device is equipped with 5 A standard current transformer, the current load box is equipped with 5 A load value 2.5 VA-60VA, the voltage load box is equipped with 100 load values from 1.25 VA-158.75VA which can basically meet the requirements of users. Load box can switch automatically when measuring
4.The device can be used to measure the specification and non-specification of the transformer, and the user can specify the measurement of any percentage point when measuring
5.it has the interface to print different test report, and also can export test date
Those functions as below are optional based on actual testing requirements, and if require any extra functions, we have professional engineer service you .
III. Main Parameter:
1.Environment condition :
Temperature:5ºC~40ºC
Relative humidity:<80%(25ºC)
height above sea level <2500m
power frequency 50Hz±0.5Hz
supply voltage 220V±5V
2. Measuring range
in-phase component(%) : 0.0001~200. resolution ratio: 0.0001
Orthogonal Component (sub) 0.001~700.0 resolution ratio:0.001
impedance(Ω) : 0.0001~20.0 resolution ratio: 0.0001
admittance (ms) 0.0001~20.0 resolution ratio 0.0001
3.Intrinsic error
in phase component :ΔX=±(X×2%+Y×2%±2 character)
quadrature component :ΔY=±(Y×2%+±X×2%×34.38)±5 character
"X","Y"--Display value of instrument
"5 Words "-- Quantification Error of Instrument
Dial indicator :1 class
4.Scope of work:
current (1%-149%)In (In=5A)
(5%-149%)In (In=1A)
working load: current :To to Tx<0.12W cosφ=1.0
IV. Regular components
No. | Product Name | Model No. | Specification | QTY | Remark |
1 | flash speed multi-position transformer calibration device | HMQH(12)-C | 1set | No. 5,6,7,8 installed into No.1 and 2 | |
2 | Automatic Transformer calibration device | HMQA-C | |||
3 | transformer calibrator | HMQA-C | 1.0 class | ||
4 | CT PT load box | FY98 | 5A,100V | ||
5 | CT PT load box | FY98 | 1A,100V/√3 | ||
6 | Voltage control section | ||||
7 | Primary line, secondary line | ||||
8 | Data management software | ||||
9 | Precision CT with riser | HL-S33SC | 5-2000A/5A,1A;0.05S class | 1pc | Regular turns ratio |
10 | self-boosting Precision PT | HJ-S6,10G3 | Primary:6,10kV;6,10/√3kV;Secondary:100V,100/√3V;0.05 class | 1pc | Dry-type |
11 | self-boosting Precision PT | HJ-S35G3 | Primary: 35kV;35/√3kV;Secondary:100V,100/√3V;0.05 class | 1pc | Dry-type |
12 | instrument | 1set | |||
13 | Computer and printer | Lenovo computer,HP printer | 1set | Optional |
V. Service on-site